Herunterladen Inhalt Inhalt Diese Seite drucken

Gastros InductWarm 200 Built-in Betriebsanleitung Seite 34

Vorschau ausblenden Andere Handbücher für InductWarm 200 Built-in:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Working Steps
1. Marking the recess: to do this, lay the device upside down, flat on the worktop and mark the outline
with a sharp pencil. Observe the dimensions 588 mm x 331 mm and the perpendicularity in the drawing
opposite.
2. Marking opening in the table plate: similarly, the opening in the table plate must also be marked by
copying the already drawn outlines to an inner outline that is scaled down by 5 mm.
3. Cutting out the opening: cut out the opening in the table plate (see 2.) using a suitable tool. Cleanly
carve out the 4mm recessed area opposite the table surface for the device support with a suitable tool
(e.g. a router) since the corresponding edges remain visible edges. For materials other than wood, please
check with your shop fitter for the correct method.
4. Plugging in supply line: plug the supply line into the device and feed the cable down through the
opening in the table plate. Ensure the plug is secured properly.
5. Placing the mounting frame: place the device onto the incorporated table edge in the installation
position and check the evenness with the table plate surface together with the glass plate. Rework if
necessary. Please note: the device should be oriented depending on the operating side desired. Consider
carefully the ventilation point as well.
6. Sealing the cut surface: after checking the accuracy of fit, it is recommended to seal the cut surface
against the penetration of fluids.
7. Laying cable: expertly fix cable in the sideboard under the table plate. Ensure that the cable is not
accidentally chafed by moving parts and subjected to tensile loads. There should be no drawers under
the installation device.
8. Masking the surface: it is recommended to mask the joint edges along the glass plate and the
worktop surface with suitable crepe tape sufficiently wide to enable clean and quick operation.
9. Filling joints: grout the constant 2 mm wide circumferential groove evenly with a suitable joint sealer
®
(e.g. Sikaflex
-221) according to its handling instructions. Joint sealer is not included in the scope of
delivery. Please only use materials suitable for food areas! Pay particular attention to selecting suitable
joint sealer (e.g. natural stone silicone) for stone worktops to prevent discoloration. Also ensure an
absolutely clean groove to prevent contamination in the joint sealer.
10. Applying joints neatly: Apply joint sealer with the help of a sealant applicator.
11. Leaving joint sealer to dry
dry.
34

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Gastros InductWarm 200 Built-in

Inhaltsverzeichnis