c.) Functional description with CONNECTED fence system (earthing + fence)
Flashing green:
Control light
fence
Flashing red:
1
(1)
Flashing green:
Control light
Flashing
2
earth (2)
red:
Connection variants:
Fence system closed:
Fence systems may be operated independent of each other at the fence connections (5 or 6).
The measured value indicated in the display (1) and the associated indicator light are nevertheless only
capable of displaying the exit exactly with maximum energy (6). If the indicator light flashes faster than once
per second, the appliance must be disconnected at once and checked by a technician before it can be used
again.
New function in accordance with EN 60335-2-76
Following a delay time of 15 seconds this device delivers an output energy of no more than 5 joules.
With an increasing load the device increases its output energy after a delay time has lapsed and therefore
automatically adjusts the shock strength to the increased growth, weather conditions and fence status.
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system
regularly, in accordance with the conditions of use, at least once per day.
visual check of the appliance and the fence system
-
measurement of the minimum voltage of 2500V at each point of the fence
-
State of fence ok = output voltage > 3500V = minimum requirement
State of fence faulty = output voltage ≤ 3500V, see operating instructions
enclosed, possible sources of error (fig. 2, pg.5)
State of connection to earth ok; earth voltage < 1000 V
State of connection to earth faulty, earth voltage ≥ 1000 V, see operating
instructions enclosed, possible sources of error (fig. 2, pg.5) and connection to
earth (pg.4)
Erdung
earth
Fence system open:
5
earth
Version : 2020.1