BVS CA - GX0 - _ _ _ _ _ _ - _ _ _ _ _ _ - XAS2
3 PRODUCT DESCRIPTION
3.5.1 Power I/O
www. matrix-vision.com
www.matrix-vision.com
The BVS Industrial Camera is powered via the Power I/O plug which additionally pro-
vides digital I/Os:
Four PLC compliant inputs as optocoupler with current limiter (11...24 V)
Four outputs as high-side-switches (10...24 V and 700 mA) with direct drive out-
put for high power flash, relays, or actuators
12-pin M12 socket, A-coded
Pin
1
2
3
4
5
6
7
8
9
10
11
12
1
Using POE and an external power supply at the same time, the external power supply
will be treated prioritized.
NOTE
The digital sensor inputs correspond to the guideline concerning
inputs. EN 61131‑2, Type 3.
The maximum load on any output is 700 mA. The load or supply
must be limited accordingly.
Description
Function
1
PWR_IN+
11...25 V power supply
PWR_IN-/GND
Ground
DigOut3
Output
Opto DigIn0
Optocoupler input
DigOut2
Output
DigOut0
Output
Opto GND
Ground for optocoupler
Opto DigIn2
Optocoupler input
Opto DigIn3
Optocoupler input
+24V_HSD
24 V supply for the high side outputs
Opto DigIn1
Optocoupler input
DigOut1
Output