ENGLISH
4.
Replace the water filler plug, com-
plete with gasket.
5.
Open pressure line (open tap or
spray nozzle) for any air to escape
during priming.
6.
Start pump (see "Operation").
7.
Turn pump OFF when water runs
out steadily.

6. Operation

Pump and suction line must be con-
nected and filled (see "Prior to Opera-
tion").
A
Caution!
The pump must not run dry.
Ensure there is always sufficient
pumping medium (water) available.
If the motor does not start, no pres-
sure is built up or similar effects are
evident, switch the pump OFF – and
try to resolve the fault (see "Trouble
Shooting").
Pump characteristic curve
The pump characteristic curve shows
which pump capacity is possible in
dependance on the delivery head.
(Pump characteristic curve for 0.5 m
suction head and 1" suction hose.)
(Pump characteristic curve for 0.5 m
suction head and 1" suction hose.)
16
(Pump characteristic curve for 0.5 m
suction head and 1" suction hose.)
6.1

Commissioning

3
Note:
The pump runs as long as the
ON/OFF switch is switched ON.
1.
Plug power cable in.
2.
Switch pump on with the ON/OFF
switch.
3.
Open pressure line (open tap or
spray nozzle).
4.
Check to see that the water comes
out!
A
Caution!
With a closed pressure line do
not let pump run for more then
10 minutes, otherwise there could be
damage by the water overheating in
the pump.
6.2
Starting a pump with
Hydromat (HWA)
3
Note:
A pump with installed Hydromat is oper-
ational as long as the ON/OFF switch is
turned ON.
P 3300 S
The Hydromat
starts the pump when water is
required (when opening the dis-
charge line the water pressure falls
off to below the cut-in pressure);
turns
the
10 seconds after closing the dis-
charge
increases in the closed discharge
line);
turns the pump off to prevent dry
running when no water is pumped
(air in suction line).
pump
off
approx.
line
(water
pressure
20
21
22
20 Power indicator (green)
21 Pump indicator (white)
22 Reset button
1.
Plug power cable in.
2.
Check to see that the power indica-
tor (20) is illuminated.
3.
Open discharge line.
4.
Press the reset button (22). The
pump will start running.
If there is no water pumped after
approx. 10 seconds the Hydromat
will turn off.Then press and hold the
reset
button
(22)
emerges.
If no water emerges after approx. 3
minutes, check the suction line.

7. Care and Maintenance

A
Danger!
Prior to all servicing:
1.
Turn OFF.
2.
Unplug.
3.
Ensure that pressure is relieved
from the pump and connected
accessories.
Service and repair work other than
described here must be left to quali-
fied specialists.
7.1

Danger of Ffreezing

A
Caution!
Frost damages the pump and
accessories, as both always contain
water!
When there is danger of freezing,
dismount the pump and accessories
and store at a frost-free location
(see below).
7.2
Pump Dismounting and
Storing
1.
Turn pump OFF and unplug.