ice may form on the coils. If the room temperature is above
35°C, the compressor will automatically shut off to protect it-
self.
WARNING
sons directly to the airflow. Adjust the airflow direction.
ble to this danger. The inside fan is running at high speed.
Covering them may deteriorate air conditioner performance or
cause it to become inoperative.
let.
occur.
wiring regulations.
outlet.
any kind.
supply cord.
plug which may cause electric shock or fire.
by the manufacturer, its service agent or qualified persons in
order to avoid a hazard.
power supply cord.
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
without supervision.
CAUTION
wall. (Fig. G)
moisture, the surface of the unit may get covered with a mist.
Wipe off any mist before it has a chance to get on the floor or
rug.
foodstuff, animals, plants, precision appliances, arts and med-
icine.
a place which is subjected to the direct air flow of the unit.
THE REFRIGERANT FOR MODEL TAD-126E AND TAD-129E
Appliance is filled with flammable gas R-32. The used refrigerant
for the model TAD-126E and TAD-129E is the fluoride R-32, which
is specially cleaned. Compared to common refrigerants, R-32 is a
nonpolluting refrigerant with no harm to the ozonosphere. The in-
fluence upon the greenhouse effect is also lower. R-32 has got very
good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling. The refrigerant of
R-32 is flammable and inodorous. Furthermore, it can leads to ex-
plosion under certain conditions. Though the flammability of the re-
frigerant is very low and ignited only by fire, read the below warn-
ing carefully.
WARNING
Downloaded from
www.Manualslib.com
manuals search engine
clean, other than those recommended by the manufacture.
service center. Any repairs carried out by unqualified person-
nel may be dangerous.
operating ignition sources. (Ex.: open flames, an operating gas
-
appliance or an operating electric heater.)
-
with a floor area larger than 4m
follow manufacturer's instructions only.
-
3. OPERATION
OPERATING STEPS:
1.
PRESS "POWER" BUTTON (C1) TO "ON".
2.
PRESS MODE BUTTON (C5).
Press the mode button (C5) to set your desired operation
mode "Cool" (C7), "Dehumidify" (C8) or "Fan" (C9).
Cool mode (C7)
During the "Cool" mode the air is cooled and hot air is ex-
hausted from the exhaust outlet.
NOTE: During Cool mode, you can adjust set temperature and
FAN speed.
Dehumidify mode (C8)
Air is dehumidified as it passes through the unit, without being
in full cool mode.
In "Dehumidify" mode operation, you cannot change the fan
speed.
Fan mode (C9)
The "Fan" mode provides only circulation of room air, so that
you cannot set the room temperature.
NOTE: All mode indicators on the unit will be OFF. Fan speed
can be adjusted.
3.
PRESS TIMER / TEMPERATURE ADJUST BUTTONS (C6)
Press timer button (C4) to enter into timer setting mode. Under
this mode, press "+" or "−" button (C6) to adjust the timer set-
ting. Timer setting will increase or decrease 0.5 hour by press-
ing "+" or "−" button within 10 hours, while timer setting will
increase or decrease 1 hour by pressing "+" or "−" button be-
yond 10 hours.
After timer setting is finished, the unit will display temperature
if there's no operation for 5 seconds. The status will be shown
on the digital indicator if timer function is started up. Under
timer mode, press timer button again to cancel timer mode.
4.
PRESS FAN SPEED BUTTON (C3)
Press the fan speed button (C3) to set the desired air flow rate
in "Cool" mode and "Fan" mode.
Auto · · · · · · · · Operation at air flow automatically accord-
ing to ambient temperature
High · · · · · · · · Operation at a high air flow
Med · · · · · · · · Operation at a medium air flow
Low · · · · · · · · Operation at a low air flow
5.
STOP OPERATION
Press the Power button (C1) and all lights will go out.
SLEEP MODE OPERATION
Press "Sleep" button (C2) to enter into sleep mode. When the unit
operates at Cooling mode, preset temperature will increase 1°C by
1 hour. After 2 hours, the unit will keep operation at this
temperature all the time.
NOTE: Sleep function is only for Cool mode, and not available for
Fan, Dehumidify, and Auto mode.
HORIZONTAL ADJUSTABLE LOUVER (A2)
CAUTION:
Do not adjust the horizontal louvers to the lowest or the highest
position during the Cool or Dehumidify mode with the fan speed
set to Low for an extended period of time, condensation may form
on the louvers.
2