Residual current circuit breaker
When the installation is protected by means of a residual current circuit breaker, which trips when the
appliance is connected, this may be due to moisture in the heating element. When an appliance
containing a heater element has not been used for a long period or stored in a damp environment,
moisture can enter the element. This should not be seen as a fault, but is simply rectified by
connecting the appliance to the main supply via a socket without a safety cut-out, so that the moisture
can be eliminated from the element. The drying time can vary from a few hours to a few days. As a
preventive measure, the unit should occasionally be run for a short time when it is not being used for
extended periods of time.
Packaging
Packaging materials are chosen with consideration to environment and are therefore recyclable.
Handling of product at end of working life
This product may contain substances necessary for functionality of product but potentially dangerous
for the environment. The product should not be disposed mixed with general household waste but
delivered to a designated collection point for environmental recycling. Please contact local authority for
further details of your nearest designated collection point. Recycling of used products saves earth's
resources and reduces global footprint.
Controls
When using this product as a local space heater according to Ecodesign Regulation (EU) 2015/1188,
it must be supplemented with one of the following approved controls. Please note that a relay-box RB
is also required, respectively a suitable contactor switch.
easy 1-Eco, electronic clock-thermostat for damp locations (IP67) and industrial environment,
including:
Electronic clock-thermostat with weekly timer
 Room temperature control with open window detection
TAP16R, electronic thermostat, including:
 Electronic room temperature control plus week timer
 Room temperature control with open window detection
TAP16R and SKG30, black-bulb-sensor, including:
 Electronic room temperature control plus week timer
 Room temperature control with open window detection
 Black-bulb-sensor
RB123, relaybox with 3 step output control and PDK65, presence detector, including:
 Two or more manual stages, no temperature control
 Working time limitation
 Room temperature control with presence detection
The product can be controlled in a different way, e.g. by an overall control system (BMS), but in
that case the responsibility lies with the installer to ensure that the control system is
programmed to make the installation meet the requirements of Ecodesign Regulation (EU)
2015/1188.