Mounting and Connection Instructions Mains/charger unit 12 V DC / 18 Ah
10.

Technical data

Rated operating voltage
Operating voltage range
Frequency
Power rating
Power consumption
Output voltage range
Ripple
Maximum constant current
Max. charging current
Accum. type
Approved accum. capacity as per VdS
Min. approved accum. capacity as per EN
No. of connectable accumulators
Current consumption as per VdS at 18 Ah accum. capacity:
-
for 12 hours, Power failure delayed < 1 min.
-
for 13 hours, Power failure delayed 1 hour.
-
Current consumption of power supply on accum. operation
Permanent accumulator monitoring
Max. period of time for recharging to 80%
Trigger voltage for accum. fault message
Trigger voltage for accum. shutdown, Deep discharge protection
Property of the fault outputs "S" and "N"
Environmental class as per VdS
Environmental class as per EN 50131-1
Operating temperature range
Storage temperature range
Relative humidity
Weight
Dimensions
Inspection and calibration
1)
Depending on the charge state of the accum.
Honeywell Security Group
Novar GmbH
Johannes-Mauthe-Straße 14
D-72458 Albstadt
www.honeywell.com/security/de
P00227-10-002-04
2016-11-22
© 2016 Novar GmbH
100 V to 240 V AC
90 V to 264 V AC
50 Hz to 60 Hz
24 W
typ. 45 W / 92 VA
1)
12.8 to 14.2 V DC
max. 300 mV peak to peak
1.5 A
0.5 A
Lead accum.
18 Ah
1.2 Ah
1
approx. 1.436 A
approx. 1.316 A
64 mA
present
72 h
11.5 V
10.6 V
12 V DC / 5 mA
I
Class II
-10 °C to +40 °C
-25 °C to +70 °C
max. 75% non-condensing
280 g
152 x 84 x 51 mm
not required