Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Operation - Toya Vorel 81773 Originalanleitung

Universell digital messgerat
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
DESCRIPTION
A multifunction meter is a digital measuring instru-
ment designed to measure various electrical or
physical quantities. The meter has a plastic casing,
liquid crystal display, and a range/measured quantity
switch. The casing has measurement jacks fi tted.
The meter comes with test leads terminated with
plugs. The meter is sold without a battery.
Before using the meter, read the instruction man-
ual in its entirety and keep it for later use.
CAUTION! This meter is not a measuring instrument
within the meaning of the Metrological Act.

TECHNICAL DATA

Display: 3 1/2 digits LCD – greatest displayed result:
1999
Sampling frequency: approx. 2–3 samples per second
Overload marking: "1" sign displayed
Polarity marking: "–" sign displayed before the result
Battery: 6F22, 9 V
Fuse: F 0.5 A/250 V
Working temperature range: 0 to 40
humidity <75%
Storage temperature: –10 to +50
humidity <85%
Outer dimensions: 145 x 75 x 35 mm
Weight (without batteries): 177 g
CAUTION! It is forbidden to measure electri-
cal values exceeding the maximum measuring
range of the meter.
Parameter
Ref. no.
Range
200 mV
2 V
20 V
81773
200 V
600 V
Overload protection: ranges 200 mV and
Notes
600 V DC: 220 V AC RMS; other ranges:
600 V DC or 600 V AC RMS
10
O R I G I N A L
C at relative air
o
C at relative air
o
DC voltage
Resolution
Accuracy
100 μV
±(0.5% +3)
1 mV
10 mV
±(0.8% +5)
100 mV
1 V
±(1.0% +5)
GB
Range
200 V
600 V
Overload protection: 600 V DC or 600 V AC RMS
Range
200 μA
2 mA
20 mA
200 mA
10 A
Overload protection: fuse 250 mA/250 V; range 10 A,
Range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
Open circuit voltage approx. 3 V;
Overload protection: 15 sec, max. 220 V AC RMS
Transistor test
Range
hFE
Measurement conditions:
I
= 2 μA; U
B
CE
Accuracy: ±(% of indication + weight of the least
signifi cant digit)

OPERATION

CAUTION! To avoid the risk of electric shock, dis-
connect the test leads and switch off the meter be-
fore opening the casing.
I N S T R U C T I O N S
AC voltage
Resolution
100 mV
1 V
Direct current
Resolution
1 μA
1 μA
10 μA
100 μA
10 mA
unfused
Resistance
Resolution
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
Diode test
hFE
Measurement conditions
0 ~1000
I
= 1 mA
F
= 1 V
Accuracy
±(2% +10)
±(2% +10)
Accuracy
±(1.8% +2)
±(2.0% +2)
±(2.0% +10)
Accuracy
±(1.0% +10)
±(1.0% +4)
U
= 1.5 V
R

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis