7. Technical data

7.1 Electrical data

Supply voltage U
Power consumption without load
Output signals
• Input/output frequency
• Level
• Offset (static, Kx type)
• Amplitude tolerance (Kx type)
• Amplitude ratio (Kx type)
Electromagnetic compatibility
(EMC)
Connection
Insulation stability

7.2 Mechanical data

Module (m)
Width of the toothed wheel
Admissible air gap
Operating temperature
Storage temperature
Protection class
Vibration resistance (IEC 68-T2-6)
Shock resistance (IEC 68-T2-27)
Weight
Housing
GEL 244
Downloaded from
www.Manualslib.com
B
− Kx type
− Tx type
manuals search engine
5 VDC ± 5%, reverse battery protected
≤ 1 W
two 90° phase-shifted sine- or square-wave signals
(see Type coding) and their inverse signals, short-
circuit proof; optionally with reference pulse
0 to 200 kHz (C
= 5 nF for Kx type)
L
500 mV
(= 1 V
difference signal)
ss
ss
compatible with TTL and RS422/485
-60 mV to +60 mV
-20% to +10%
û
= 0.9 to 1.1
A
B
industrial applications: EN 50081-1 and 2,
EN 50082-1, EN 61000-6-2
2
9 x 0.14 mm
, screen not connected on the probe
side; sealed cable outlet, 0.3 m; max. cable length
100 m (observe the voltage drop on the power
line!)
500 V
0.3, 0.5
≥ 4 mm (material: ferromagnetic steel)
0.10 ± 0.02 mm with module 0.3
0.15 ± 0.03 mm with module 0.5
-30 °C to +85 °C
-40 °C to +120 °C
IP 68
2
200 m/s
2
2000 m/s
30 g
plastic: Polyphenylene sulfide (PPS), fibre-
reinforced