Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Lenord+Bauer GEL 244 Betriebsanleitung

Inkrementaler zahnradgeber mit sinus- oder rechteck-ausgangssignal
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
Boring and milling scheme:
4.3 Removal of the probe
Only remove the MiniCoder with the distance gauge attached!
STOP
Without the distance gauge the permanent magnet in the MiniCoder will attract
the measuring system to the tooth profile thus possibly causing the measuring
system being damaged.
Mechanical impacts onto the measuring surface of the MiniCoder will
damage the system!
⇒ Insert the distance gauge between the MiniCoder and the measuring toothed wheel
⇒ Loosen the two M4 screws
⇒ Remove the MiniCoder
Avoid any mechanical contact between the measuring system of the MiniCoder
and the tooth profile!

5. Electrical connection

According to the type of MiniCoder (see Type code on page 15) the following pin layout is
applicable:
Line
color
white
brown
pink
black
grey
yellow
green
red
blue
18
Downloaded from
www.Manualslib.com
Signal/function
Track
K
KM, KN
1
/1
2
/2
N
/N
Sense
U
= +5 V ± 5%
B
0 V (GND)
manuals search engine
27
0,1
4 H6 2 deep
A
B
~ ~
r
a
B
A
Axis of rotation
r
= d
/2 (d
= OD of toothed wheel)
a
a
a
T
TN
measures in mm
Screen is not wired
in the probe.