Herunterladen Inhalt Inhalt Diese Seite drucken

YATO YT-85170 Originalanleitung Seite 14

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
GB
Assembly in the Blower mode
Mount the nozzle on the air outlet.
The nozzle base is fi tted with two pins to be inserted into the gaps in the air outlet assembly socket (II).
Push the nozzle onto the socket until it stops and turn it clockwise (III).
This will lock the nozzle's position and prevent it from any accidental detachment during operation. Ensure the assembly has been
correct. The edges of the nozzle and the sockets must be in contact around the entire circumference, and pulling the nozzle must
not cause its detachment.
The Blower is now ready for use.
Assembly in the Vacuum mode
Mount the nozzle on the air inlet (IV) and the collection bag (V) on the air outlet. Install the nozzle and the collection bag following
the description in the section "Assembly in the Blower mode".
The collection bag comes with a zip fastener, which must be zipped along its entire length.
Fit the collection bag so that the bag is not twisted and the zip is facing downwards.
The Vacuum is now ready for use.
Starting and stopping the appliance
Make sure that the switch is in the OFF setting, completely released and its action is not hindered in any way, and upon releasing,
it returns to the OFF setting automatically and instantly.
Plug the power cord plug in the power outlet.
Hold the appliance by the handle and make sure that neither the air inlet nor the air outlet is obstructed. Make sure you do not
direct the nozzle outlet airfl ow at any person, animal or object. Press the switch with fi nger to start the appliance (VI). Allow the ap-
pliance to run for approx. 1 minute at maximum speed. During this time, observe the appliance for malfunctions. If you notice any
signs of malfunction, e.g. excessive vibration, excessive noise, a smell or smoke emitted by the appliance, immediately release
the pressure on the switch, wait until the rotation comes to a complete stop, then put the appliance down, unplug the cable from
the power outlet and perform an inspection of the appliance.
The appliance is switched off by releasing the switch. Wait until all moving parts have come to a complete stop, then unplug the
cord from the power outlet and store the appliance.
Switch lock feature
The switch is equipped with a lock which locks it in the ON setting. This allows for releasing the hold on the switch throughout the
work time. This reduces the stress of your hand and, as a result, your fatigue during prolonged use.
The lock can only be enabled after the switch is pressed. Press the lock button, and then release the pressure on the switch. The
switch will remain activated without the need to hold it.
Release the lock by pressing the switch again. The appliance stops when you release the lock and release the pressure on the
switch.
Speed Control
The appliance features a dial for stepless speed control within the range given in the Specifi cations table. Altering the speed
results in a change in the blow/vacuum rate of the appliance.
Change the rotational speed by turning the dial. The higher the setting visible on the dial, the higher the speed.
Instructions for use
Always make sure that the inlet, outlet and the nozzle are not obstructed. Increased noise and vibration will be the fi rst sign if
any of these is partly or completely obstructed. Restore the fully unobstructed condition immediately. Working with an obstructed
appliance is ineffi cient and can cause overheating and damage to it.
Before starting work, check the work area thoroughly, removing any objects that may cause a hazard if propelled by an air blow.
Also, remove any objects that may cause a hazard by being moved unexpectedly by an air stream, e.g. when tipped over.
Provide a safety zone of at least 15 m wide from the working area. The safety zone must not be accessible to any persons, espe-
cially children. Persons who enter the safety area must exercise caution and wear the personal protective equipment described
above in the Manual.
Always direct the Blower nozzle downwards, towards the ground to be cleaned. Do not blow debris in the direction of other people
or animals.
Do not blow air towards a surface which is too loose. The dust generated during such use impairs the ability to watch the workpla-
ce, which does not allow for an appropriate response in the event of an emergency.
As far as possible, direct the airfl ow in the same direction as the wind. This will prevent debris from moving into the area already cleared.
Before starting the vacuum always mount the collection bag correctly. Check the amount of debris in the bag regularly during
operation, and empty it. Filling the collection bag excessively will lead to blockages.
O R I G I N A L
I N S T R U C T I O N S
14

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis