Herunterladen Inhalt Inhalt Diese Seite drucken

Pellini ScreenLine SL2776 Installationanweisungen Seite 21

Battery module
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Within 20 seconds hook the battery module onto the
base plate to be memorized;
4. The yellow LED on the up arrow will turn on and then
start flashing quickly. Wait  10  seconds until it flashes
more slowly;
5. Within 10 seconds send the cancellation command of
all channels by pressing the up and down push buttons
simultaneously on any remote control (set on any
channel), until the purple LED on the battery module
starts flashing: all channels have been deleted.
NOTE: the procedure can be suspended anytime by
pressing again the programming button of the battery
module.
For further instructions on using the remote control, refer
to the dedicated instruction manual.
RESTARTING THE BATTERY MODULE
If the battery module is not working properly, it is possible
to restart it by following the procedure described below:
1. Detach the battery module from its base plate;
2. Plug the battery charger into a power socket;
3. Plug the micro-USB connector into the port provided on
the battery module;
4. Pull out the connector.
The restart of the battery module is acknowledged by the
yellow LED on the up arrow turning on.
Should the malfunction persist, it is possible to manually
force the module restart:
1. Detach the battery module from its base plate;
2. Press the programming button on the battery module
for at least 10 seconds. Also in this case, the restart of
the battery module will be acknowledged by the yellow
LED turning on.
LOGIC INVERSION
Should the blind operate in reverse (namely when the down
push button is pressed the blind raises and vice-versa), it
is possible to invert the operation logic, by following the
procedure below:
21

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Pellini ScreenLine SL2776

Inhaltsverzeichnis