6. Join luminaire with bracket by the means of wire (3) using lock washer(3) and M3 nut (5)
(included).
7. Connect the luminaire to the mains supply according to polarity: GND - yellow-green, L -
brown, N - blue.
8. Lock the luminaire at the bracket using M4 countersunk screw(6)(included).
9. Motion sensor adjustment panel.
9.1. "LUX" - adjusting daylight sensor. The sensor allows to turn on luminaire when surrounding
illumination decreases below threshold set. When sensor is set into "sun"(max) position it
operates
both at day and night. When sensor is set into "3" position it operates when
surrounding illuminationis below 3 lux.
9.2. "SENS" - sensor distance. Detection distance when low sensivity "-" is set is 2 meters, when
high sensivity "+" is set - 16 meters.
9.3. "TIME" - adjusting of delay timer (time when luminaire remains on at 100% power after no
motion is detected by motion sensor). Minimal delay time is 10±3 s, maximal delay time - 12±1
minutes.
These instructions assume expert knowledge corresponding to a completed professional
education as an electrician.