Herunterladen Inhalt Inhalt Diese Seite drucken

Disposal; Troubleshooting; Spare Parts; 10 Accessories - resideo Braukmann SG160S Einbauanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.
Slowly open shut-off valves on inlet and outlet
6.3 Adjusting the setting scale
If the adjustment knob is removed, this setting is lost. A new
setting can be achieved using a pressure gauge.
1.
Close shut-off valve on inlet
2.
Release pressure on outlet side (e.g. through water
tap)
3.
Close shut-off valve on outlet
4.
Fit pressure gauge
5.
Loosen slotted screw
8

Troubleshooting

Problem
SG160S and SG160SD
Drips
Check valve does not close off tightly in
the front pressure area
Too little or no water pressure
SG160SD only
Water is escaping from the spring bonnet Diaphragm is faulty
Too little or no water pressure
The outlet pressure set does not remain
constant
9

Spare Parts

For Spare Parts visit homecomfort.resideo.com/europe
MU1H-1346GE23 R0420
GB
6.
7.
8.
9.
10.
7
Observe the local requirements regarding correct waste
recycling/disposal!
Cause
During the heating up of the water heater no error, normal function
Continually drips from soiling
Pressure increase in the front pressure
area
Seal surfaces dirty or worn
Cut-off fixtures before or after the safety
group not opened entirely
Safety group not installed in the flow
direction
Pressure reducing valve is not set to the
desired outlet pressure
Filter in pressure reducing valve is
contaminated
Filter in pressure reducing valve is
contaminated or worn
Valve insert, sealing ring or edge of
nozzle is contaminated or worn
Rising pressure on outlet (e.g. in boiler) Check check valve, safety group etc.
Expansion water from the hot water
purifier

10 Accessories

For Accessories visit homecomfort.resideo.com/europe
5
• Do not remove slotted screw
Slowly open shut-off valve on inlet
Set desired outlet pressure (e.g. 4 bar)
Align scale (e.g. 4) in middle of viewing window
Re-tighten slotted screw
Slowly open shut-off valve on outlet

Disposal

Remedy
Actuate lifting grip multiple times so that
dirt particles are flushed out, or replace
as necessary
Replace check valve
Replace check valve
Open shut-off valves fully
Install safety group in flow direction
(observe arrow direction on housing)
Replace diaphragm
Set outlet pressure
Replace filter
Replace filter
Replace valve insert
Inspect check valve before the hot water
purifier and single-lever mixing valve if
necessary
Close shut-off valves to the hot water
purifier supply line. Open hot water tap
connection. Does pressure remain
constant? Expansion water of the hot
water purifier. Does pressure increase?
Pressure reducer defect

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Braukmann sg160sd

Inhaltsverzeichnis