4.4 AC Voltage

1. Insert the red test lead in the "INPUT" jack and the
2. Move the rotary switch to the"
3. Read measured voltage on the display.
Use extra caution when measuring high voltages to
avoid electric shock or damage.
Do not attempt to measure voltages above 600V AC to
prevent injury or damage to the meter.

4.5 AC Current

1. Move the rotary switch to the "
2. Press the trigger and insert one conductor inside the
3. Read measured current and the frequency value on the

4.6 DC Current

1. Move the rotary switch to the "
2. Press the trigger, open the clamp and insert one
3. Read measured current on the LCD display.
NU-720C_0218.indd 27
Downloaded from
www.Manualslib.com
black lead in the "COM" jack.
the test leads across the circuit or load to be measured.
proper range.
jaws. Only clamp one conductor, multiple conductors
with different current directions will cancel out readings.
LCD display.
proper range
conductor inside the jaws only clamp one conductor
multiple conductors with different current directions will
cancel out readings.