SAFETY WARNINGS

The operator of this device must be instructed in the speci c dan-
gers associated with using this device and in the essential safety
measures before working with it for the rst time and at least once
a year thereafter.
The operating company must:
• make the operating manual available to the operator and
• ensure that the operator has read and understood it.
Use protective equipment. Always wear goggles when using the
device. The use of protective clothing is recommended, such as dust
mask, protective gloves, sturdy non-slip footwear, helmet and ear
defenders.
Never hold your ngers or other body parts in the working area of
the indenter or the latch.
Remove the battery pack before starting any adjustment, cleaning
and maintenance work on the device.
Only use devices, battery packs and chargers that are in perfect
technical condition.
Have damage repaired immediately by an authorised workshop.
GB
To avoid injury and damage, prevent accidental starting of the
device.
Remove any setting tools and wrenches before the operation.
Do not work on electrically live parts. Device is NOT insulated.
WARNING! To reduce the risk of re, personal injury, and product
damage due to a short circuit, never immerse your device, battery
pack or charger in uid or allow a uid to ow inside them.
Corrosive or conductive uids, such as seawater, certain industrial
chemicals, and bleach or bleach containing products, etc., Can
cause a short circuit.
Compliance with the speci ed service work and service intervals is
mandatory.
Never break open battery packs and chargers and store only in dry
rooms. Keep dry at all times.
Use only System M18 chargers for charging System M18 battery
packs. Do not use battery packs from other systems.
To avoid injury and damage, never immerse the tool, removable
battery or charger in liquid or allow liquid to penetrate them.
WARNING
This device contains a button-type/coin cell lithium battery.
A new or used battery can cause severe internal burns and
lead to death in as little as 2 hours if swallowed or if it enters the
body. Always secure the cover on the battery compartment. If it
does not close securely, stop the device, remove the battery and
keep it out of reach of children. If you believe that someone has
swallowed the battery or that it has otherwise entered the body,
seek immediate medical attention.
CRIMPING TOOL SAFETY WARNINGS
Crimping tool must only be used by trained personnel in electro-
technical applications.
Check crimping tool, latch and indenter for cracks and other signs of
wear before each use.
Only use crimping tool in perfect technical condition.
Only use the crimping tool with inserted connection material.
Do not touch the latch and indenter during the pressing operation.
In the event of problems during the crimping process, immediately
release the ON switch and press the unlocking button on the
hydraulic system. The valve will open and the piston will return to
its initial position.
English
Deutsch
12

RESIDUAL RISK

Never crimp live connecting materials.
SPECIFIED CONDITIONS OF USE
The pressing tool may only be used for pressing connecting materi-
als according to the device speci cation.
All live parts, i.e., parts conducting electricity, must be discon-
nected in the technician's work environment prior to starting work.

WORKING INSTRUCTIONS

Only use connection items according to device speci cation.
Consult the documents provided by the manufacturer for handling
and assembly instructions for connectors.
Before the crimping process begins, the battery capacity must be
checked: minimum 33% (see illustrated description). It may require
charging before work commences.
Actuating the control switch initiates the pressing process, which is
characterized by the movement of the indenter.
It is the user's responsibility to check and evaluate that the joint
is correct.
Imperfect joints must be crimped again using a new connector.
Action in the event of faults
• Keep the reset switch pressed until the indenter has opened
completely
• check the battery capacity
• Check the cable and the connection item according to the
technical data.
• If it is suspected that a live cable has been pressed, the crimping
tool must be inspected at an authorized, specialist workshop
WARNING: To reduce the risk of explosions, electric
shock and damage to property and equipment, never press
live electrical cables.
Device is NOT insulated. Contact with a live circuit could
result in severe injury or death. Turn o power before
pressing. Keep hands away from the latch and indenter.
Laceration and amputation can occur.
Always remove battery pack before changing or removing
accessories. Only use accessories speci cally recommended
for this device. Others may be hazardous.
To reduce the risk of injury, wear safety goggles or glasses
with side shields.
MAINTENANCE
Remove the battery pack before starting any adjustment, cleaning
and maintenance work on the device.
Never open the device, removable battery or charger.
Check the device for any problems such as noise or jamming of
moving parts that could be a ecting the device.
Check crimping tool, latch and indenter for cracks and other signs of
wear before each use.
Clean and grease the devices when you have nished work.
Clean and grease the indenter, the latch release lever and the latch.
Check the smooth running of the moving parts
Replace the latch and the indenter when they become chipped or
damaged.
The ventilation slots of the device must be kept clear at all times.