Herunterladen Diese Seite drucken

turck PT1100 Kurz- Betriebsanleitung Seite 2

Drucktransmitter

Werbung

PT1100/PT2100
Technical Data
Pressure range
PT1100
PT2100
Relative
-1...+60 bar
-1...+600 bar
Absolute
0...6 bar
Permissible overload
≤ 4 bar 2.5 x FS
≤ 400 bar 3 x FS;
> 600 bar 2.5 x FS
Burst pressure
> 4 bar 2.5 x FS
< 400 bar 6 x FS;
> 600 bar 4 x FS
Temperature
Medium
FPM: -40...+125 °C
-40...+125 °C
EPDM: -40...+125 °C
NBR: -20...+100 °C
Environment
-40...+100 °C
Storage
-50...+100 °C
Materials
Housing
stainless steel 1.4404/AISI 316L
Connector
polyacrylamide 50 % GF UL 94 V-0
Media contact:
sealing material FPM, EPDM, NBR, measuring element ceram-
ics Al2O3 (96 %) pressure port stainless steel 1.4404/AISI 316L
Electrical specifications
Output
Supply
Load
2-wire 4...20 mA
7.5...33 VDC
Supply voltage -7.5 V
<
[Ω]
0.02 A
3-wire 0...5 V
7...33 VDC
> 10 kΩ/< 100 nF
0...10 V
12...33 VDC
> 10 kΩ/< 100 nF
ratiom. 10...90 % 5 VDC ± 10 %
> 10 kΩ/< 100 nF
Reverse polarity protection
short-circuit proof and reverse-polarity protection, with max.
supply voltage.
Dielectric strength
500 VDC
Protection class
protection class III
Dynamic behavior
Response time
< 2 ms, typ. 1 ms
Load change
< 100 Hz
Accuracy (incl. zero point, full scale, linearity, hysteresis and repeatability)
Characteristic line acc.
± 0.5 [% FS]
IEC 61298-2
(considering EMC interference < μ1.5% fs)
Resolution
± 0.1 [% FS]
Temperature behavior
max. /- 0.2 [% FS/10K]
Long-term stability acc. to IEC 
max. /- 0.3 [% FS/10K]
61298-2
Tests/Approvals
Electromagnetic compatibility noise immunity/noise emission:
ISO 13766 earth-moving equipment
DIN EN 13309 - construction equipment
DIN ISO 14982 - agriculture and forestry
automotive guideline ECE R10 (E1 approval for customer
specific type on request)
automotive guideline 2004/104/EG (E1 approval for
customer specific type on request)
EN 61326-2-3 - pressure transducer (types M12 × 1 only)
CISPR11
noise immunity automotive guideline:
ISO 11452-2, HF (Field), 100 V/m (200...2000 MHz)
ISO 11452-4, HF (BCI), 100 mA (20...400 MHz)
ISO 10605, ESD, ±15 kV contact, ±15 kV air
ISO 7637-2 3 (Pressure sensor for 12 V and 24 V power
system, 0...5 V, 0...10 V and 4...20 mA), Pulse 1, 2a, 2b, 3a,
3b (test level 4)
ISO 16750-2, load dump, 155 V (1 Ω, 300 ms)
Shock acc. ISO 16750-3
50 g, 11 ms, half sine wave, 1000 ×/axis
Continuous shock IEC 68-2-29 40 g for 6 ms, 1000 x all 3 directions
Vibration acc. ISO 16750-3
test VI (12 g sinusodial, 18 g random vibration)
UL
E302799 acc. to ANSI/UL 61010-1
The date of manufacture can be seen on the label of the pressure transmitter:
YYMMDD
-
XXX
-
XX
-
XXX
Date as year-month-day
internal identification order position
Single part number
Hans Turck GmbH & Co. KG | Witzlebenstraße 7, 45472 Mülheim an der Ruhr, Germany | Tel. +49 208 4952-0 | Fax +49 208 4952-264 | more@turck.com | www.turck.com
Current
consumption
< 23 mA
< 7 mA
< 7 mA
< 7 mA
© Hans Turck GmbH & Co. KG | D102067 2017-12 DE EN

Werbung

loading

Diese Anleitung auch für:

Pt2100