Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Inspection; A) Before Each Use - Sav 531.01 P Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 531.01 P:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Maintenance and inspection:

a) Before each use:

- Visually inspect the entire magnet.
- Wipe clean pole shoes and surface of the load sufficiently and, as the case may be, remove
burrs and bumps using a file.
- Check the function of the switching mechanism and handle lock.
- Do not use the magnet if you find any defects.
b) Weekly:
- Check the entire magnet including hoisting eye, locking block, and screws for deformations,
cracks and other defects. If the hoisting eye is deformed or if its diameter is worn off by more
than 10 %, it has to be replaced by the manufacturer.
- Check the existence and readability of type plates and instruction signs.
- Inspect the pole shoes. If more than 10 % of their surface is damaged (holes, scores, etc.)
they need to be reground by the supplier or another authorized workshop.
The lifting capacity is tested after each intervention.
c) Annually:
At least once per year have the nominal holding force of the load lifting magnet be verified
by the manufacturer or an authorized supplier (European standard UNI EN 13155:2004).
Adhere to the ruling health and safety regulations!
In addition to fulfilling the legal requirements, it is recommended to observe the following maintenance
schedule:
Action
Inspect pole shoes for damages
Inspect hoisting eye and switch for
damages and safety deficiencies
Check type plates
Acceptance test (certificate) for safe
working load (SWL)
BAL 531.01
OPERATING INSTRUCTIONS
for permanent magnetic lifting magnet
WORKHOLDING AND AUTOMATION
Daily
Technical Data subject to change without prior notice
Frequency
Weekly
Monthly
EN
Annually
21

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für Sav 531.01 P

Inhaltsverzeichnis