CV
Beschreibung
1
XpressNet slave address
2
Bus
3
debounce
4
Radio band
5
Radio channel
6
programming lock
7
software version
7
2 Reset ranges selectable
8
Manufacturer ID
7+8
Reg8 = CV address
Reg7 = CV value
9
Radio ID
10
K1 address high
11
K1 address low
12
K1 time delay
13
K1 inversion
14
K1 configuration
15
K2 address high
16
K2 address deep
17
K2 time delay
18
K2 inversion
19
K2 configuration
20
K3 address high
21
K3 address deep
22
K3 time delay
23
K3 inversion
19
CV-Table
S
L/W
Bereich
1
0 – 32
0
0
20
0 – 255
0
0 -2
0
0 – 255
160
0/160
–
–
Decoder-Resetfunktionen
11
16
160
–
Registerprogramiermodus
165
0 – 255
0
1 - 2048
1
0
0 – 255
0
0/1
6
0 – 6
0
1 - 2048
2
0
0 – 255
0
0/1
6
0 – 6
0
1 - 2048
3
0
0 – 255
0
0/1
Bemerkung
0 = disabled, 1-32 slave address
0 = XpressNet
100ms / value debounce time inputs
0 = 434 Mhz
1 = 868 Mhz
2 = 915 Mhz (US)
radio channel
Module is completely reset
Programming lock (CV 6)
read only
CV 7/8 retain their value
First describe the CV 8 with destination
address, then write or read CV 7 with value
(eg: CV 19 should have 3)
➔ CV 8 = 19, CV 7 = 3 send
Radio ID for feedback
Switch address which is confirmed or
switched (depending on configuration)
Message delay / delay switch
0 = normale
+1 inverted switch INPUT
+2 inverted switch DIRECTION
see Annex 1
Switch address which is confirmed or
switched (depending on configuration)
Message delay / delay switch
0 = normale
+1 inverted switch INPUT
+2 inverted switch DIRECTION
see Annex 1
Switch address which is confirmed or
switched (depending on configuration)
Message delay / delay switch
0 = normale
+1 inverted switch INPUT
+2 inverted switch DIRECTION
RBM