Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data (Standard Configurations) - Indel Webasto Isotherm INOX DR49 Installations- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für Isotherm INOX DR49:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 71

5 Technical data (standard configurations)

Operating voltage: 12 or 24 VDC
Average consumption measured with an internal temperature of +5°C and an
external temperature of 25°C.
The average consumption is greatly influenced by the refrigerator's usage mode and
the type of ventilation.
Refrigerant: R134a (the system's capacity is indicated on the refrigerator's data
plate).
The refrigerators meet the requirements of the EMC directive and bear the CE
marking.
Model
DR 49
DR 55 FREEZER
DR 65
DR 65 NO FROST
DR85
DR130
DR 105
DR 160 FRIDGE
DR 160 FREEZER
DR 160 FRIDGE
DR 160 COMBO
DR190
60
Instantaneous
consumption
12/24Vdc (Amperes)
6.0/3.0
7.0/3.5
6.0/3.0
6.0/3.0
6.0/3.0
6.0/3.0
6.0/3.0
7.0/3.5
10.0/5.0
10.0/5.0
10.0/5.0
7.0/3.5
Instantaneous
consumption
12/24Vdc (Watt)
72
85
72
72
72
72
72
85
120
120
120
85
User Manual
Average
consumption at
25°C (Watt/24h)
400
740
470
320
370
429
480
530
1100
1100
1100
700

Werbung