Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use - R+M Suttner St-83 Kurzanleitung Und Sicherheitshinweise

Desinfektions-kalt-nebelgerät
Vorschau ausblenden Andere Handbücher für ST-83:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Operation manual
ST-83 cold fog disinfection device. Article no.: 200083500
3
4
Security
Hazard! If these instruc-
tions are not complied with,
there is a risk of life and
limb and property damage!
Read this User Manual
thoroughly before using the
unit!
Keep the User Manual in a
safe place for later refe-
rence or the subsequent
owner!
This User Manual was
established using utmost
care. However, we do
not accept any liability for
possible mistakes in this
User Manual and their
consequences.
Formation of
aerosol!
An aerosol can arise from
disinfectants! In order to
avoid inhalation, wear a
suitable respiratory pro-
tection! Ensure suffi cient
ventilation!
Page 1, Ver. 05.2020
Description
The ST-83 disinfection device can be used for different areas of appli-
cation:
Disinfection of rooms - apartments - hotels - guest rooms - vehicles
(taxi - public transport - vehicle preparation - patient transport - driving
schools) caravans - mobile homes - sanitary facilities, production facili-
ties pest control in stables and other rooms, for air humidifi cation - dust
binding etc.
Attention!
Please note compliance with the currently applicable precautionary
measures!
Please observe all instructions and precautions according to the
operating instructions. It may only be operated by trained specialist
personnel. The guarantee of the device is linked to compliance with
these operating instructions. If the user violates the regulations descri-
bed, the warranty is generally void.

Intended use

Can be nebulized:
Water for air humidifi cation and dust control - disinfectant * mixed with water as a working
solution * (hydrogen peroxide 3%, peracetic acid 1%) pesticides - liquids containing acids
and solvents only with special FKM version.
Using other or mixing different agents can lead to unforeseen chemical reactions and
damage the device.
Warranty claims cannot be made in such a case. No agents may be used which contain
fl ammable components in explosive doses or which can form fi re-hazardous mixtures when
atomized. No other chemically aggressive or toxic substances such as solvents or paints
may be used.
Despite the high quality standards, no general chemical resistance can be guaranteed for
mixtures of substances. No guarantees are given for substances that have not been re-
leased in writing beforehand. Mixing the application solution should be done in an external
container. If this is done in the device container, the water content must always be fi lled in
fi rst.
The drinking water that may be used must comply with all requirements of the current
version of the Drinking Water Ordinance.
Please remember to check that in showers and other aerosol-forming units that use drin-
king water, the drinking water must be checked for legionella in accordance with the legal
regulations (e.g. once a year)?
There are special designs for various acids and solvents.
The agents can have a very different nature, they can be water-soluble or insoluble pow-
ders, they can be liquid or oily. The agents are mixed with a small amount of water and fog
additives to form a fog broth. The medium broth can be viscous, but must not contain any
solid components over 0.3 mm.
The information provided by the medium manufacturers must be observed and the manu-
facturer should be consulted if anything is unclear.
In the case of acidic disinfectants in particular, consultation with the manufacturer is neces-
sary due to the low dilution.
It is always a good idea to carry out a test mist before using it on a large scale.
www.rm-suttner.com