Montage:
• When connecting the device, pay attention to the designation "IN" (input or mains
side) and "OUT" (output or consumer side) as well as on the arrow direction inside
the electronics cover.
OUT
• Codes/Standards DIN VDE 0661 and DGUV Information 203-006 (former BGI/GUV-I 608)
Connection cable
Connection cross-section
Stripping length
Wire stripping length
cable diameter
Length connection cable
• Only use household plugs and connectors (VDE 0620) or industrial plugs and connec-
tors 16A 3p 6h (IEC/EN 60309-2)!
• Strain relief: Install clamp in the correct position depending of the cable diameter!
Clamp
position with
cable 3G1mm²
Tightening torque:
Ncm
3G1,0 mm²
3G1,5 mm²
3G2,5 mm²
1,5m +10% before protective device
min. 1,5m after protective device
Housing screw
180
H05BQ-F
H07BQ-F
35 mm
7 mm
Ø 7,3 - 14 mm
Clamp position
with cable
3G1,5-2,5 mm²
Strain relief
80
IN
H07RN-F
Contact screw
80