Herunterladen Diese Seite drucken

Brine-To-Water Hydraulic Module; Heat Pump Module - Glen Dimplex SIW 6TES Montage- Und Gebrauchsanweisung

Sole-wasser wärmepumpe für innenaufstellung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
3.2 Brine-to-water hydraulic
module
The brine-to-water hydraulic module contains the components
of the heating and brine circuit required for connecting the heat
pump.
5
6
7
1)
De-aeration
2)
Heating pressure gauge
3)
Brine pressure gauge
4)
Domestic hot water cylinders
5)
Overflow valve
6)
Pipe heater
7)
Heat circulating pump
8)
Brine circulating pump
9)
Domestic hot water circulating pump
EN-4

3.3 Heat pump module

The refrigeration circuit is "hermetically sealed" and contains
the fluorinated refrigerant R410A included in the Kyoto proto-
col. Information on the GWP value and CO
refrigerant can be found in the chapter Device information. The
refrigerant is CFC-free, non-ozone depleting and non-combus-
tible.
The heat pump module switch box contains all components re-
1
quired for operating the refrigeration circuit.
3
2
10
4
10) Compressor
11) Liquefier
12) Evaporator
13) Filter dryer
14) Compensation pipe
9
8
452236.66.09 · FD 9912
SIW 6TES - SIW 11TES
equivalent of the
2
11
12
13
14
www.gdts.one