Fixing the canopy hood (fig.3)

• Hook the canopy hood, item C, onto the wall brackets 1
• Fit the two regulation screws, item W, of 4Mx25 (supplied) into the keyholes of the wall
brackets 1
• The canopy can be aligned or adjusted in height by using the two adjustement screws
item W.

Electrical connection and working test

• Before connecting to the mains supply ensure that the mains voltage corresponds
with the voltage on the rating plate inside the hood.
• Connect the cooker hood to the mains via a double pole switch which has 3 mm
clearance between the contacts.
• The appliance must be earthed.
• Once the electrical connection has been completed, check that worktop illumination,
motor and speed work properly.

Ducting or Recirculation fitting

• Ducting fitting
a) The cooker hood can be ducted to the outside using either rigid or flexible fire retardant
ducting of 120 or 150 mm. The choice is left to the installer. When 120 mm ducting is to
be used it will be necessary to install the reduction flange item A on the air outlet (fig.4).
b) The installer should provide suitable ducting and sealing material for the installation.
c) The cooker hood can also be ducted to the outside through one of the rectangular openings
located in either side of the lower section of the chimney stack (item I). In this case the
deflector (item D) should be fitted into the spigot (item R) to close the aperture which is
notused (fig.5).
d) If the hood is provided with the charcoal filters fitted, the filters should be removed.
• Recirculation fitting
a) The filtered air is returned to the room through the two side grilles on U-shaped lower
section I, which are either formed in the metal itself (bottom position fig.6), or as a plastic
insert, and have two different heights to deal with different needs (bottom position fig.6,
top position fig.7).
b) Lower position (fig.6): fit the recirculation spigot item R into the round outlet on top of
the canopy while pressing down on the spigot until it snaps into position.
c) Upper position (fig.7): fit the additional spigot, item P, into the round outlet on top of the
canopy while pressing down on the spigot until it snaps into position. Then fit the
recirculation spigot R into the top of the spigot, item P, and install the charcoal filters
inside the canopy.
d) Chimney hood with grilles. The two venting grilles must not be fitted into the chimney
stack until the chimney stack has been installed onto the wall above the canopy.
14