Herunterladen Inhalt Inhalt Diese Seite drucken

For Retrofitted To An Existing Heat Pump - ClimaLine Pancake Montageanweisungen

Drainagewanne / -kit luft-wasser-wärmepumpen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

S t e p B – F i x i n g t h e t r a y a d a p t e r
Before you place the drainage tray on the stand, fix the tray adapter in the
tray. It is IMPORTANT that the washer is on the TOP of the drainage tray.
Tighten the adapter with the locking screw.
S t e p C – A s s e m b l y o f t h e h e a t i n g t r a y
For new installation of heating pump
Place the Pancake between the vibration dampers on
the wall/ground stand or on the consoles for
the Ground support 270 - 370 mm, with the
tray adapter at the back and the cable to the right.

For retrofitted to an existing heat pump

Before locking the nuts on the front vibration dampers,
place the drainage tray under the pump by slightly inclining
the pump at the back and in this way opening up sufficient
space to feed in the tray from the front.
Assembling of Pancake on the 16kW outdoor unit that's
mounted on a Ground support 270 - 370 mm, it is
sometimes possible to insert the tray from the side
between the pump's feet.
The tray adapter need not be mounted for this. In this
case, fit it when the tray is inserted into place under the
pump.
S t e p D – A s s e m b l y o f t h e d r a i n a g e h o s e & h e a t i n g c a b l e
( i f a k i t i s p u r c h a s e d )
1.
Pull the heating cable through the tray adapter.
2.
Pull the heating cable through the drainage hose (easiest with the draw cable) and affix
the hose to the tray adapter, then secure the hose with a tie strap. Attach the heating cable
in the tray's cable support.

Werbung