For installation on Ground support 270 - 370 mm
S t e p A – A s s e m b l y o f G r o u n d s u p p o r t 2 7 0 - 3 7 0 m m
The drainage tray needs to be laid on brackets that are secured in the stand's inner beams.
Pull out the bracket legs and press them down into the inner beam's profile.
For new installation of a heating pump on a wall attachment/ground bracket
S t e p A – A s s e m b l y o f v i b r a t i o n d a m p e r s
The drainage tray needs 30 mm of space between stand and the heating pump.
Start therefore by securing the vibration dampers in the bracket, where the heating pump's feet
are to be located. Lower the bottom rod of the vibration damper into the stand and tighten it with
the help of a flat washer and a nut - do this with all the vibration dampers. IMPORTANT! The thick
vibration dampers should be fitted on the RIGHT side of the stand.
Thin

When retrofitted to an existing heating pump on wall/ground stand

Dismantle the heating pump's existing vibration dampers and fit the new vibration dampers,
by lowering the bottom rod of the vibration damper into the bracket and tightening it using a
flat washer and a nut; tighten the nuts moderately. Do the same with the remaining vibration
dampers. Do not tighten the nuts on the upper side before the tray has been placed under the
heating pump.
If necessary, fasten the bracket with
M8 screws/nuts
(not included)
Thick