INSTALLATION INSTRUCTIONS

WARNINGS

Installation, modifications and maintenance of the appliance must be carried out by authorized personnel in
compliance with current safety standards.
The manufacturer declines all responsibility for failure to comply with these obligations.
The instructions contained in this manual give important regarding security for installing and
maintaining the appliance. The manufacturer recommends that this manual be carefully stored in the
work zone where it can be consulted by technicians and workers.
Electric connection of the appliance must be according to the instructions given on the technical data
table and electric scheme.
Disrespect of the instruction given by producer with the appliance (Use, maintenance, electric
connection, technical data table and data plate) may compromise the appliance safety and will result in
immediate loss of the warranty. The manufacturer declines all responsibility for injury or damage to
persons or things, due to disrespect of the instructions.

INSTALLATION

This appliance is not designed for built-in installation.
Remove the protective nylon on the appliance. If sticky particles left on the appliance, clean them with
a suitable solvent.
Water connection
No connection is required since the appliance is filled manually.
Water drain
Open the global valve in the bottom of the tank and discharge the water in the tank.
Important : The tank drain must be connected to the drainage system using a pipe resistant to high
temperatures (100°C).
Electrical connections
The appliance is designed to operate at the voltage indicated on the data plate.
Each appliance must be connected to the power supply by a suitably dimensioned independent line (the
total power is indicated in the "Technical data" table). A flexible rubber cable with insulation
specifications not lower than type H 07 RN-F must be used for connection to the terminals.
The length of conductors between the cable clamp and terminals must be such that the live wires are
pulled taut before the ground wire (yellow-green) if the cable is worked loose from the clamp.
Multi-pole main isolating switches of suitable current rating. (with minimum contact-breaking distance
of 3 mm) must be installed, as well as automatic residual current switches of suitable high sensitivity.
There should be a automate fuse between the appliance and the network.
Voltage changes should not exceed
Ground connections and equipotential bonding
The appliance must be connected to the ground circuit using the terminals marked by the symbol
located next to the connection terminals.
%10V.