Herunterladen Inhalt Inhalt Diese Seite drucken

Lanaform S1 Gebrauchsanweisung Seite 8

Vorschau ausblenden Andere Handbücher für S1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
BREAKDOWNS AND REMEDIES
EN
In the event of a malfunction, under normal conditions of use, please refer to the following chart:
The dehumidifier is not working
The fan runs but not the compressor
No air is emitted through the
appliance's exhaust vent
Very noisy appliance
No or little dehumidification
Hot air emission
The humidity level selected has not
been reached after a lengthy period
Water noise
8
Problem
The appliance is not connected
The appliance is not connected
The water tank is full or incorrectly
positioned
The temperature of the room is
too low.
The room's level of humidity is too
low.
The compressor is no longer running
The appliance is running in self-
cleaning mode
The filter is dirty
The appliance is incorrectly
positioned
The filter is dirty
The filter is clogged
Temperature too low
The level of humidity selected is
higher than the actual level of
humidity in the room
The water drainage pipe is
obstructed or bent
The operating time is too short
-
Doors and windows have not been
closed or the room is not sufficiently
air-tight
Coolant flow
Possible cause
Solution
Plug in the appliance or check your
power supply to see whether it is
faulty.
Connect the appliance.
Empty the water tank and/or
reposition it in the main unit
The appliance stops the
dehumidifier program if the
temperature is below 5°C.
The humidity level selected is above
that of the room or is below 40%.
The temperature around
the condenser is below 0°C.
The appliance will stop the
dehumidifying function and trigger
the anti-freeze programme before
restarting.
No air is emitted after 30 minutes of
self-cleaning for a short period
Clean the filter
Move the appliance onto a
stable, hard surface or place an
anti-vibration mat under the
dehumidifier.
Clean the filter.
Clean the filter
The dehumidifying capacity may be
reduced if the room temperature
is below 18°C. Try and increase the
temperature.
Select a level of humidity that is
lower than the level of humidity in
the room.
Check the drainage pipe and replace
it if necessary.
Wait until the dehumidifying time
is sufficient.
The condenser is emitting hot air.
The appliance is not malfunctioning.
Close the doors and windows or
try and improve the room's air-
tightness
Normal effect.