Herunterladen Inhalt Inhalt Diese Seite drucken

Lanaform S1 Gebrauchsanweisung Seite 6

Vorschau ausblenden Andere Handbücher für S1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 28
To install the carbon filter, follow the instructions below:
EN
• Open the compartment (1).
• Insert the carbon filter (2).
• Replace the air filter grid in the compartment (3).
Note: you do not have to insert the carbon filter when you use the appliance to dehumidify the air in a room In fact, the
absorption capacity of the air is reduced if the carbon filter is inserted.
USING THE S1 DEHUMIDIFIER
A. Dehumidifier function
The principle of the dehumidifier involves the suction of humid air from the room. This air is then filtered and directed
to a condenser at a lower temperature (the compressor compresses a refrigerant gas, which lowers the temperature of
the condenser), the effect of which is to turn the water vapour in the air into water, which is then collected in a tank. The
"dried" air is returned to the room. The most comfortable relative humidity for human beings is between 45% and 55%.
The dehumidifier can operate in manual or automatic mode.
Important note: before operating the dehumidifier, you must first adjust the exhaust vent (7) before switching on the
appliance.
Use in manual mode:
• To configure the dehumidifier in manual mode, you must select "CO" when adjusting the humidity level.
• To do this, connect the dehumidifier. The operating indicator (17) starts to flash. Next, adjust the angle of the exhaust
vent (7).
• Then press the On/Off button (10) to switch on the dehumidifier. The operating indicator light will be constantly green.
• Select "CO" by pressing the Humidity/Timer keys (12 and 13).
The dehumidifier will run continuously in manual mode, whatever the level of humidity in the room in which the
appliance is installed.
Use in automatic mode
• In automatic mode, you can set the level of humidity you require. This may vary between 30% and 80%.
• To set the level of humidity, first select the On/Off key(10) followed by the Humidity/Timer keys (12 and 13) to select the
level of humidity required.
• Once selected, the level will flash for a few seconds before displaying the room's actual level of humidity.
• The appliance adjusts itself automatically to maintain or reach the level of humidity selected. The dehumidifying process
will therefore start within 5 minutes of the appliance starting. Once the level of humidity selected is 3% higher than the
level of humidity in the room, the dehumidifying process will stop but the fan will continue running. Once the level of
humidity selected is 3% higher than the level of humidity in the room, the dehumidifying process will stop but the fan
will continue running.
Automatic anti-freeze
• The appliance is fitted with an automatic ant-freeze system. If the temperature of the room is below 5°, the dehumidifier
program cannot run.
• The dehumidifier is also fitted with a second temperature detector located close to the condenser. Its role is to measure
the temperature of the air in this area and thus prevent any risk of freezing, which could affect normal operation of the
appliance. If the temperature detected is below 0°, the compressor will stop and the anti-freeze program will automati-
cally start. When the detector's temperature is above 5°C, the dehumidifier will restart.
• The following table indicates average water quantities extracted over a 24-hour period based on a range of temperatures
and levels of humidity* for information purposes: