Herunterladen Inhalt Inhalt Diese Seite drucken

Putting Into Service; Air Supply; Operating Procedure; Adjusting The Vacuum Extraction - Avdel Genesis G3 HD Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

P u t t i n g i n t o S e r v i c e
A i r S u p p l y
All tools are operated with compressed air at an optimum pressure of 5.5 bar. We recommend the use of pressure regulators and
automatic filtering systems on the main air supply. These should be fitted within 3 metres of the tool (see diagram below) to ensure
maximum tool life and minimum tool maintenance.
Air supply hoses should have a minimum working effective pressure rating of 150% of the maximum pressure produced in the system
or 10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and should be armoured where
operating conditions may result in hoses being damaged. All air hoses MUST have a minimum bore diameter of 6.4 millimetres or
inch.
Read servicing daily details page 17.
O p e r a t i n g P ro c e d u r e
Ensure that either the correct nose assembly or swivel head
suitable for the fastener is fitted (see pages 8-11 and 13-15).
Connect the tool to the air supply.
Insert the fastener stem into the nose of the tool. If using a nose
assembly, the fastener should remain held in by the vacuum
system. If not, adjust the vacuum extraction rotary valve 60.
If using a swivel head, the vacuum extraction is disabled but the
jaws themselves will grip the fastener.
Bring the tool with the fastener to the application so that the
protruding fastener enters squarely the hole of the application.
Fully actuate the trigger. The tool cycle will broach the fastener
and with standard nose assemblies the broken stem will be
projected to the rear of the tool .
Item numbers in bold refer to the general assembly drawing and parts list on pages 22-23.
STOP COCK
(USED DURING MAINTENANCE
OF FILTER/REGULATOR OR LUBRICATION UNITS)
3 METRES MAXIMUM

ADJUSTING THE VACUUM EXTRACTION

Using a screwdriver, turn rotary valve 60 until the air flow at
the rear of the tool ceases.
With the nose of the tool pointing downwards, insert a
fastener into the nose and hold it into position.
Turn the rotary valve either way until there is sufficient suction
to retain the fastener.
E n g l i s h
8
PRESSURE REGULATOR
AND FILTER (DRAIN DAILY)
/
1
4
TAKE OFF POINT
FROM
MAIN SUPPLY
MAIN SUPPLY
DRAIN POINT
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis