ELECTRICAL CONNECTION
NOTICE !!!
Connection to power grid should be done by a qualified electrician with
appropriate license.
Electrical installation must include a switch in which the distance between
contacts of all poles is no less than 3 mm. The installation must be made with
the power turned off!!!
Connecting the ventilator:
- remove the front (1) and cover of the central part of the body (3)
- move the power lead using the hole in the body of the ventilator (7)
- place the lead in the connection block (6) keeping in mind the picture below
Connecting the thermostat:
- lead the conductor to the back part of the thermostat base (12) as in the picture
below
PHASE
NEUTRAL
L
N
3
4
1
THERMOSTAT
VENTILATOR
MODE OF USE
The ventilator starts operating once the thermostat is turned (13).
Programme the desired temperature according to the scale C.

MAINTENANCE

Before beginning maintenance, switch o the power.
Maintenance must be performed at least one a year by a quali ed electrician.