Herunterladen Inhalt Inhalt Diese Seite drucken

Product Description; Technical Data - Dea LIVI Bedienungsanleitung Und Hinweise

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 63

2 PRODUCT DESCRIPTION

Models and contents of the package
The name LIVI identifies a series of electromechanical operators for sliding gates with different features as to motor and control board
power supply voltage, capacity, mechanical adjustment of force, electronic clutch and built-in limit switch. All automated models involve
the use of advanced control units (NET series) equipped with anti-crushing sensor, built-in 433 MHz radio receiver, speed control and
slow down in opening and closing. The LIVI models are intended primarily for residential / condominium and Semi-intensive/intensive
use depending on the duty cycle foreseen for the automation.
LIVI is completed by a set of accessories listed in the "PRODUCT ACCESSORIES" table (page 167).
LIVI is composed of a mechanical gear motor which rotates the driving gear; This gear, coupled to the rack properly installed on the
gate, converts the circular motion of the gear motor into rectilinear motion thus allowing the movement of the gate on its own guide.
Inspect the "Contents of the Package" (Pic. 1) and compare it with your product for useful consultation during assembly.
Transport
LIVI is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all information that
may be provided on the same box for storage and handling.

3 TECHNICAL DATA

Motor power supply voltage (V)
Absorbed power (W)
Max Thrust (N)
Work cycle (leaf L=5m)
Maximum n° of operations in 24 hour (leaf L=5m)
Built-in capacitor (µF)
Operating temperature range (°C)
Motor thermal protection (°C)
Opening speed (m/min)
Weight of product with package (Kg)
Protection degree
*
Leaf max 400kg
Power supply (V)
Rated power transformer (VA)
Fuse F2 (A) (transformer)
Batteries
Fuse F1 (A) (batteries input)
24V operators outputs
Warning: The above values are calculated by taking the maximum power
supplied by the respective processors. In absolute terms, the maximum
current from each output must not exceed 10A.
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
22
403E - 6NET
230 V ~ ±10% (50/60 Hz)
320
340
18 cycles/hour
60
8
140 °C
11
CONTROL BOARD
NET24N
230 V ~ ±10% (50/60 Hz)
80 VA (230/22V)
1A
2x 12V 1,3A
15A
1x 5A
24 V
(24V_AUX + 24V_ST =
max 200mA)
24 V
max 15 W
24V
max 5W or max
1 art. 110
24 V
max 15W
-20÷50 °C
433,92 MHz
HCS fix-code - HCS rolling
code - Dip-switch
100
OPERATOR
803E - 9NET
5/24NET/F
450
490
210
11 cycles/hour
22 cycles/hour
40
12,5
-20÷50 °C
160 °C
10
12,5
IPX4
Power supply (V)
Fuse F2 (A)
Fuse F1 (A)
230V operators outputs
Auxiliaries power supply output
Safety devices power supply output
"Warning" output
Electric lock output
230V Flashing light output
24V Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
5/24NET/F-
8/24NET/F
BOOST (*)
24 V
80
110
240
260
18 cycles/hour
60
40
-
-
16
10
12
NET230N
230 V ~ ±10% (50/60 Hz)
5A
160mA
2 x 600W
24 V ~
(24V_AUX + 24V_ST
= max 200mA)
24V
230 V ~ max 150W
max 1 art. 110 or 24V
output max 5W configurable
230 V ~ max 40W
24 V
max 100mA (for led
flashing light) art. LED24AI or
open gate warning light/courtesy
light
-20÷50 °C
433,92 MHz
HCS fix-code - HCS rolling code -
Dip-switch
100

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Dea LIVI

Inhaltsverzeichnis