E N G L I S H
e) Belt loops broken
f) Missing tamper indicating ball from yellow
lever on band assembly.
If the M-20.2 EEBD fails any of the listed
inspections or if at any time during its life the
pressure gauge is out of the green zone or the
indications of abuse are observed, the unit should
be removed from service.
HOW TO CARE FOR
THE M-20.2 EEBD
The M-20.2 EEBD is designed to be belt worn or
stored in a confined space environment.
However, like all escape breathing devices it is
not indestructible.
Abusing your M-20.2 EEBD is risking your life in
the event of an emergency.
Abusing someone else's M-20.2 EEBD should be
considered a criminal offense.
Your life may depend on the care you give your
M-20.2 EEBD. Avoid the most common abuses:
3
1. If the M-20.2 EEBD is accidentally opened,
DO NOT close it, remove it from service.
2. DO NOT drop the M-20.2 EEBD, particularly
when taking off the belt to which it is
attached.
3. DO NOT clean the M-20.2 EEBD with anything
other than a soft brush.
4. DO NOT immerse the M-20.2 EEBD in water.
5. DO NOT sit on the M-20.2 EEBD.
6. DO NOT drag the M-20.2 EEBD on the ground.
7. DO NOT place the M-20.2 EEBD near heat
greater than 70°C.
8. DO NOT put tape or stickers on the
M-20.2 EEBD that would impede its opening
or the reading of the gauge.
WHEN TO USE THE M-20.2 EEBD
The M-20.2 EEBD should be used immediately at
the first indication of fire or explosion, even if
smoke is not visible. Carbon monoxide is odorless
and colorless. You could breathe a fatal amount of
carbon monoxide before smoke is present. If you
suspect an oxygen deficient atmosphere, put on
the M-20.2 EEBD, don't wait!