2. For a safety conscious work environment

• Protect the unit from dust. Use the unit on dry wor-
king places only.
• Qualified and trained persons must use the device
only.
• Before putting the device into operation, the user
has to read the operating instructions and ask the
manufacturer in case of any questions.
• Use the unit when in perfect and clean condition only
and with fully operational UVA and blue fluorescent
light tubes.
• Before switching on the device, the light protection
lid has to be attached.
• The nitrogen gas cylinder must always be used with
a pressure reducer.
• Do not cover the ventilator of the unit. Do not put any
objects through the venting slots.
• Connect the device to permissible sockets only.
• Please adhere to the acknowledged safety regulations.
• This device is used for the processing of UV-curing
materials in a spectral range of 360 - 390 nm.
Please also adhere to the processing manual for each
material being used.
• Do not pull the mains plug out off the socket at the
mains cable.
• Should the mains cable be damaged, it must be
replaced at once. Defective mains cables must not
be used.
• The device must be repaired by the manufacturer
only.
• The unit must be switched off during service and
maintenance operations (cleaning, replacing of UVA
and fluorescent light tubes or reflecting foil). Pull the
mains plug beforehand!
14
2
• When exchanging use the original egger light tubes
and reflectors only.
• Do not use any dissolvent when cleaning the device.
Do not immerse the unit in liquids.
• Children must be kept away from the unit.
!
On self-accomplished repairs or if other spare parts
are used, all guarantee and liability claims will become
extinct!

3. Installation, Handling and Initial Operation

3.1 Scope of delivery

Please check whether the delivery is complete and whe-
ther all parts are free from transport damage. Immedia-
tely inform us or the distributor about missing parts or
transport damage.
The UV-curing unit egger EL 1 plus N
1 light protection cover
1 mains cable
1 metal plate for lacquering operations
1 plastic box with removable lid
1 gas connecting tube; length 1.5 m; diameter 6 x 8 mm
1 operating instructions and processing manual
Therefore, the device can be put into operation right
away.
3.2 Technical data of the light-curing unit egger EL 1plus N
Power supply:
230 V +/- 10% (or 115 V)
Mains frequency: AC 50 Hz/60 Hz
Connection:
mains plug Schuko (German)
Power input:
AC 250 A
Gas:
Nitrogen 2.6