Herunterladen Inhalt Inhalt Diese Seite drucken

Comet Spa DSG-10 EX Bedienungsanleitung Seite 22

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 41
EN
In order to work at 10 BAR, if the temperature
on the thermoregulator has been varied, it is
necessary to set the thermoregulator at 180°C.
COMPARATIVE TABLE OF DEGREES
° C
BAR
133,91 3
CENTIGRADE AND STEAM PRESSURE
144,00 4
EXPRESSED IN BAR
152,22 5
159,22 6
165,34 7
170,81 8
175,77 9
180,31 10
WARNINGS
- The machine is pre-set at the max temperature
of 180 °C.
- For any adjustment, timing or replacement
intervention not described in this handbook,
contact the Builder or the Reseller qualified
personnel.
- It is possible to make various adjustments to
adapt the machine to the various production
needs.
Timer set
- Keep the two keys ③ "+" and ③ "-" pressed
at the same time for 10" seconds
- After that press ③ "+" or ③"-" to set a time
from 0' to 120' minutes
- Press the gun lever and release it, the steam will
come out and the countdown will start
- Steam will stop coming out when the
countdown will reach 0'
To stop the timer, at any time, just press and release
the gun lever.
Note: the factory setting is on 0', Timer not
working
If the Timer remains set to 0' (factory setting) the
steam generator operates continuously.
Adjustment of the quantity of steam and
detergent
Adjust the quantity of steam and detergent by
means of the two knobs situated on the machine
left side:
⑧ The left knob varies the quantity of steam by
turning it clockwise or counter-clockwise.
⑦ The right knob varies the quantity of detergent
by turning it clockwise or counter-clockwise
MACHINE START
Electric controls
The machine is equipped with an electric control
panel-board situated in the machine front side.
The various devices present on the panel-board are
described below:
Reference - Descripion
① - MAIN SWITCH: It is a 2-position selector that
energises the machine if turned to ON.
Vice versa, the machine is de-energised if
turned to OFF.
② - LINE orange pilot light: it turns on when the
machine electric system is energised.
③ - THERMOREGULATOR: refer to paragraph
"Temperature adjustment".
④- Display:
- Hour meter
- Thermometer
- H2O - TANK WATER LEVEL sound allarm: it turns
on to signal a lack of water in the tank.
⑤ - BOILER START push-button: it starts the boiler.
⑥ - GUN START push-button: it starts the gun.
Steam gun
Use of the steam gun
⑳ Put the gun plug in the special socket then
block it by means of the two levers;
⑥ Press the GUN STAR orange luminous push-
button situated on the control panel;
22

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dsg-15 exDsg-18 exDsg-21 exDsg-30 ex

Inhaltsverzeichnis