CONDENSER OVERHEATED
Condenser overheated alarm. Condenser reaches to the first critical temperature. Please plug out the product.
Clean the condenser and wait 30 minutes. Then restart the product again. If the alarm continues please contact
technical service.
COMPRESSOR BLOCKED ( for high condensing )
Condenser reaches to maximum critical temperature limit. Compressor will not work in this condition and the
electrical energy of the device will be off. Please plug off the product and clean the condenser and wait 60
minutes. Then restart the product again. If the "COH" and "CSd" alarms continue contact technical service.
IMPORTANT WARNIING: "CONDENSER OVERHEATED" and "COMPRESSOR BLOCKED" alarms can also occur in
where the ambient temperature is high. Please note that in this case the ventilation of the place must be
checked. These alarms may lead to compressor failure and won´t covered by guarantee.
THE DIGITAL PARAMETER SETTING HAS BEEN PROGRAMMED FOR THE UNIT TO PERFORM THE BEST WAY. DO
NOT CHANGE ANY OF THE PARAMETER SETTING OTHER THEN SIMPLY SETTING THE TEMPERATURE. TO
CHANGE THE PARAMETERS SETTINGS CAN CAUSE SERIOUS PERFORMANCE DECRESAES AND CREATE SERIOUS
PROBLEMS IN THE UNIT.