Herunterladen Inhalt Inhalt Diese Seite drucken

Taurus ALPATEC AC 351 KT Bedienungsanleitung Seite 21

Mobiles klimagerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
FAN MODE:
- Press mode to select fan mode fan indicator
turns on.
- Press speed to select high, mid or low speeds.
- In that mode, press Speed for 5 seconds to run
the internal dry function, i.e. both upper and
lower fans work simultaneously. Press Speed
for another 5 seconds to cancel the internal dry
function.
- Temperature is not adjustable.
- Press Swing to turn off or turn on the up/down
swing function.
DEHUMIDIFYING MODE:
- Press "MODE" to select dehumidifying mode,
dehumidifying mode indicator turns on.
- Remove the plug of drainage cap, insert a tube
and put the other side of the tube into water
containers or drain channels.
- When entering dehumidification mode, if the
room temperatures is ≥17ºC, the compressor
will start to work.
- If the room temperature is ≤15ºC, compressor
stops; when the temperature rises back to
≥17ºC, the compressor restarts (the compres-
sor shall meet the 3minute delay protection
function).
- In dehumidification mode, the fan run in low
speed by default, and the wind speed are not
adjustable. ·Temperature cannot be set.
- NOTE: When the dehumidification function
is in use, the exhaust pipe assembly shall be
removed; otherwise it will lead to not obvious
dehumidification effect or display "FL" water full
alarm.
COMPRESSOR PROTECTION:
- Three minutes later after power on / restart,
compressor starts to run.
WATER TANK FULL PROTECTION:
- When the water level in the bottom water plate
is above the warning level, the unit will alert
automatically a.
- Please discharge water in the machine accor-
ding to chapter "water drainage".
WATER DRAINAGE:
- When the inner water tank is full, its indicator
will flash on the screen.
- The appliance enters into standby mode.
- Pull out the plug to drain out water, power off
the machine and restart it , the machine will
runs normally .
- This model have self evaporative function,
under cooling mode, please do not use continue
drainage to get better cooling effect.
- Once you have finished using the appliance:
- Turn the appliance off, using the on/off switch.
- Unplug the appliance from the mains.
ONCE THE APPLIANCE HAS BEEN USED:
- Stop the appliance by pressing button (A) on/off
- Unplug the appliance from the mains.
- Unplug the appliance from the mains and allow
it to cool down before starting any cleaning
operation.
- Clean the electrical assembly and the mains
plug with a damp cloth and dry them after-
wards. NEVER SUBMIT THEM IN WATER OR
ANY OTHER LIQUID.
CLEANING
- Wipe the appliance with a damp cloth impreg-
nated with a few drops of detergent. Do not use
solvents or products with an acidic or basic pH
factor such as bleach or abrasive products to
clean the apparatus.
- Do not immerse the connector in water or other
liquid or place it under the tap. If the appliance
is not maintained in good condition
- Cleaning, its surface can be degraded and inex-
orably affect the life of the appliance and lead to
a dangerous situation.
CLEANING THE AIR FILTER:
- Clean the air filters every 2 weeks. If the air
filter is blocked with dust, its effectiveness will
be reduced.
- Washing the air filters by submerging them
- Carefully in warm water with a neutral deter-
gent, rinse them off and let them dry completely
in a shady place.
- Install the filters carefully after having them
cleaned.
AFTER PERIODIC MAINTENANCE:
- Switch off the appliance and remove the plug.
- Separate the exhaust pipe from the air and
store it carefully.
- Put the appliance in a dry place.
- Remove the batteries from the remote control
and store them carefully.