Advice before Use
Read carefully these instructions.
As soon as the equipment is delivered, open packings and inspect
the equipment carefully.
If you notice any damage, contact immediately the transport company
and register your complaint in due form with mention of the defects.
Be sure that this equipment left our factory in perfect condition.
Check if the received equipment is consistent with the delivery notice
and if this delivery notice is consistent with your order.
If it is not, contact immediately your supplier.

General Remarks

This luminaire is a piece of lighting equipment designed for professional
use only in theatres and indoor television or movie studios.
This luminaire has been designed for being mounted on non-combustible
surfaces (
).
Designed and built in accordance with EN 60950 safety regulations, it
must imperatively be connected to earth by means of its earth wire. It also
complies with the CEI safety regulations (598-1/598-2-17 publications).
To prevent any electrical shock, there is no need to open this equipment
when functioning.
Nevertheless:
Any part or lenses have to be replaced if they are visibly damaged
and their efficiency might be reduced, for example in case of deep
cracks or scratches.
Lamp must be changed if damaged or distorted by heat.
If internal access is needed for control, service or repair purposes,
always refer to qualified personnel.
In all events, always unplug the power supply cable before opening,
lethal voltage present inside
It is the user's responsibility to use the luminaire for its intended purpose
and to check the equipment that might be connected to it.
The luminaire can under no circumstances be modified.
ADB will not assume any responsibility in case of damage resulting from
modications made to the luminaire.
This luminaire is a piece of professional equipment designed for easy
and simple use. Nevertheless, always refer to qualified personnel for
any installation or repair work.
Important Remark
Power supply cables and other connections are essential for your
equipment and contribute greatly to a safe and trouble free operation.
Always hold the plug when disconnecting a cable, never pull the
cable.
Never use cables or connectors in bad condition, check them before
installation and periodically thereafter.
Never tie power supply and data cables together.
P a g e
6
Issue 002

Fitting the Lamp

Type of lamp to use
GX 9.5 lampholder for both 1 and 1.2 kW lamps.
Light centre lenght (LCL) shall be 55 mm for a 1 kW lamp and
67 mm for a 1.2 kW lamp.
The maximum admitted lampdiameter is 28 mm; never use lamps
with a greater diameter.
Unplug luminaire power supply cable.
Open the access door to the lamp and position the lamp carrier
back by means of the fine adjustment knob.
Plug the lamp into the socket (GX 9.5 lampholder), close the door
and connect the power supply cable.
Notes:
This luminaire is set for use with a 1 kW lamp (LCL 55 mm) but it
can be adapted to take a 1.2 kW lamp (LCL 67 mm).
In this case, open the access door to the lamp, remove the reflector,
slide the lampholder out of the upper guides and back into the lower
guides (check that power supply wires are not pinched).
Put the reflector back in its place and close the door.
For optimal lamp performance, please refer to the manufacturer's
notice.
The lamp must be changed if damaged or distorted by heat.

Electrical Connection

This luminaire is designed for operating at a nominal voltage of
220 V - 240 V.
It is delivered with a cable H05SS-F T180°C 3 x 1,5 mm
In use, take care to move away the cable from the hot parts of the
luminaire.
Use IMPERATIVELY this cable with your luminaire.
For your own safety, make sure the earth wire (yellow-green) is
ALWAYS connected to earth.
Plug the cable into the power supply socket at the back end of the
luminaire. Secure the power plug with the stirrup.
If the cable or the power cord is damaged, it must be replaced with a
specific cable or power cord power cord exclusively provided by the
manufacturer or by an authorized service agent.
www.adbstagelight.com