EXCHANGING THE PULL-OUT CABLE
• disconnect the cable reel from the power supply and remove from the operation
site.
• remove the cover for the connecting terminals.
• FT / EFT disconnects the stranded wires of the upper slip ring from the fuse
terminals.
• FTE disconnect the stranded wires of the upper slip ring from the hexagon screw.
• loosen all the screws and remove the housing cover
• carefully pull the upper slip ring off the plastic axle
the spiral spring in the coil is under tension. Please ensure that the
locking mechanism is activated.
• To replace the pull-out cable, you should make sure the spring is unwound for
your own safety! Please adhere to the following instruction:
1. carefully pull on the cable stopper until the click of the notches have faded,
you immediately notice a pull on the cable stopper in the opposite direction.
2. let the coil run back slowly and count the number of turns. This is important
to adjust later the exact preload on the spring again, without damage to coil
or spiral spring. In the end the coil should be able to move freely.
3. Remove the damaged cable from the coil.
4. Unscrew the slipring (lower part) turn the slip ring over and disconnect the
cable
5. Remove strain relief.
6. Remove defective pull-out cable
7. Remove the cable stopper and where appropriate the heat shrink tubing
from the defective cable and attach to the new cable.
• Undertake the re-assembly in reverse order.
• Adjust the pre-load:
• Hold the stopper outside the housing and hold it with one hand. Now turn the coil
as often as you counted. At the end let it snap into the notches. (see "LOCKING
DEVICE")
• After the complete re-assembly undo the locking. Pull on the cable stopper, wind
out the cable complete and slowly rewind it.
• Before re-mounting at the operation area, please check for a correct
performance. (see "Ready to use")