User manual M / MV / CT / CMV

9. Commissioning:

The cooler may be disconnected from the power supply system by pulling the plug of the low
power device out of the rear side.
10. Material and refrigerant:
The type and quantity of the gas filling in the cooling unit is indicated
on the name plate of the device.

11. Temperature control:

The cooler is shipped ready for use. This unit has one temperature control for
regulating the temperature. The temperature control is located in the upper
right hand corner inside the unit.
The temperature control pre-set by the manufacturer is "4.5". As needed, the
temperature control can be adjusted clock-wise to make the product "Colder",
the control can be adjusted counter clockwise to make the product "Warmer".
Note: The regulation too cold setting (higher than "4.5") can cause the
freezing of the products.

12. Cleaning

Basic cleaning:
The basic cleaning should be accomplished every day. Thus you guarantee
a longer service life of the cooling display and a good hygienic condition. We
recommend documenting the accomplished cleaning measures.
AHT Cooling Systems GmbH – NL Deutschland
Sonntagshornstraße 19
·
83278 Traunstein
Temperature control
Settings (factory settings): Temperature control is preset in the factory
in order that the temperature of the cooled products lies constantly
between +2° C and +7° C (35.5° F and 41° F).
The cooling temperature may be slightly altered.
All internal or external surface areas which get in contact with the cooled
products are made of zinc-plated steel, aluminium or nontoxic plastics.
The applied cooling agent is approved according to federal regulations.
The cooling display is insulated with CFC-free insulation (expanding agent:
cyclopenthane).
In order to remove coarse dirt from internal and external surface areas, it is
not necessary to disconnect the cooling display from the power supply.
Note: Do not remove cover panels for basic cleaning.
Wipe all surface areas including the front door.
Do not apply sharp objects for cleaning.
Clean the internal and external housing of the cooling display with a clean
and wet cloth or with neutral soap.
In order to avoid damages, do not use coarse and highly inflammable
detergents.
·