MMB 32 mixer module
MMH 32 mixer module (mixed heating circuit)
Art.: 367780
MMH 32 mixer module (mixed heating circuit)
Article: 367790
Art.: 367780
Article: 367790
manifold
Ball valve flow with
manifold
red thermometer
Ball valve flow with
1 1/2" internal thread x 1 1/4" external thread
red thermometer
1 1/2" internal thread x 1 1/4" external thread
(Are only required for installation below
Note:
Mixer with bypass:
dual differential pressureless manifold
(Are only required for installation below
Note:
DDV 40 required, see below):
Mixer with bypass:
dual differential pressureless manifold
DDV 40 required, see below):
Open
Open
Closed
1 1/4" internal thread for heat pump
Closed
1 1/4" internal thread for heat pump
Temperature sensor NTC 2M and NTC 10M supplied. Fixed with cable connector.
Actuator already installed. Read separate documentation for electrical wiring!
Temperature sensor NTC 10M supplied. Fixed with cable connector.
boiler)
Delivered without pump! Suitable for almost all pump models DN 32, inside micrometer 180 mm
Actuator already installed. Read separate documentation for electrical wiring!
boiler)
Delivered without pump! Suitable for almost all pump models DN 32, inside micrometer 180 mm
Actuator included. Read separate documentation for installation!
Installation example:
DDV 40 dual differential pressureless manifold
Installation example:
Manifold bar VTB
DDV 40 dual differential pressureless manifold
Unmixed heating circuit WWM 32
Manifold bar VTB
Mixed heating circuit MMH 32
Unmixed heating circuit WWM 32
Mixer module bivalent MMB 32
Mixed heating circuit MMH 32
Mixer module bivalent MMB 32
Buffer tank
Buffer tank
Heat pump
Heat pump
1 1/4" external thread for manifold bar or dual differential pressureless
1 ¼" internal thread
1 1/4" external thread for manifold bar or dual differential pressurel
1 ¼" internal thread
1 ½" external thread flat sealing
1 ½" external thread flat sealing
1 1/4" internal thread to alternative heat source (e.g. oil or gas
1 1/4" internal thread to alternative heat source (e.g. oil or
MMB 32
MMB 32
Heat generator 2
Heat generator 2
Ball valve return flow with blue
thermometer and integrated
Ball valve return flow with blue
gravity control:
thermometer and integrated
Turn handle to the right:
gravity control:
•
0° - Ball valve open, gravity
Turn handle to the right:
control activated
•
0° - Ball valve open, gravity
•
45° - Ball valve and gravity
control activated
control open
•
45° - Ball valve and gravity
•
90° - Ball valve closed
control open
•
90° - Ball valve closed
WWM 32 MMH 32 MMH 32
WWM 32 MMH 32 MMH 32
DDV 40
DDV 40
VTB
VTB