Herunterladen Inhalt Inhalt Diese Seite drucken

Mechanical Installation - Entrematic Ditec Qik4E Technisches Handbuch

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 65

7. Mechanical installation

Unless otherwise specified, all measurements are expressed in mm.
-
If the surface does not allow the cabinet to be fastened strongly and firmly, prepare a con-
crete base with embedded anchor ties and QIKZ base plate which must be level and clean.
-
Insert elements made of iron or another material in the anchor ties to attach the ties to the
concrete reinforcement.
-
Pass the cable ducts through the central hole of the plate.
WARNING: make sure that the fastening is strong and firm.
-
Secure the cabinet.
i
N.B.: to open the cabinet, release the automation as described on page 40 and unscrew the
4 screws on the front.
300
230
Ø60
Ø12,5
500
700
32
400
600

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ditec qik7ehDitec qik7yeh

Inhaltsverzeichnis