1.
m

ultilimit switch

The system can be installed on the left or right.
Loosen three screws, and remove these together with the
two grease nipples and the cover.
Using two screws, secure the receiver to the body.
Insert two screws in the adapter plate, and secure the
strip to the adapter plate with three screws.
Use two screws to secure the multilimit switch to the re-
ceiver. There are three positions available. Use the two
screws to secure the strip to the base plate. Set the three
cams to their respective sensor positions (start, interme-
diate, end positions). The electrical cables can be con-
nected on both sides.
12

(Rg)

2.
b

(Fb)

ellows
Loosen two screws, and remove the wiper.
Secure the two guides with two screws each to the re-
ceiver, and secure the receiver with another two screws
to the body.
Push the bellows over the guides. Secure them to the
base plate and the receiver with two screws each.
3.
t

(tk)

elescope
Loosen two screws, and remove the wiper.