Alarm management
Configure alarms from sensors
1. Press
2. Scroll and select the alarm to be configured.
3. Scroll and select Alarm below active/Alarm above active, then scroll and select Yes or No to
activate/deactivate the alarm.
4. To only activate the alarm, scroll and select Value, then set the threshold value.
5. To enable/disable the buzzer, scroll and select Buzzer, then scroll and select Yes or No.
6. Hold down
Configure alarms from NMEA 2000/SAE J1939 network
1. Press
2. Scroll and select CAN then scroll and select the network: the managed alarm list appears.
3. Scroll and select the alarm to be configured.
4. Select Alarm active.
5. Scroll and select Yes/No to enable/disable the alarm signal through the pop-up and the indicator light
on Nav Control.
6. To enable/disable the buzzer, scroll and select Buzzer, then scroll and select Yes or No.
7. Hold down
Menu description ALARMS
Depth shallow
Depth navigation
Wind
Battery
Engine water temp
Engine oil temp
Engine oil pressure
Fuel
Fresh water
Waste water
Min RPM
CAN
64
7" TFT display | Operating instruction v. 1.0 | © 2018 Continental Automotive Switzerland AG
to access the main menu and then scroll and select ALARMS > Config alarms.
to return to the data pages.
to access the main menu and then scroll and select ALARMS > Config alarms.
to return to the data pages.
Alarm
Low water minimum threshold
Maximum threshold. For example, a value near the maximum
value measurable by the sensor.
Safety depth minimum threshold
Wind speed maximum threshold
Battery voltage minimum threshold
Water temperature maximum threshold
Engine oil temperature maximum threshold
Engine oil pressure minimum threshold
Fuel level minimum threshold
Fresh water minimum threshold
Waste water maximum threshold
Engine revolutions minimum threshold. Only values under the
threshold will be considered to trigger engine alarms.
Alarm access from CAN bus (NMEA 2000 and J1939). See
"Alarm management" on page 62
Description
Possible
Default
values/commands
0–9.9 m
2 m, buzzer Yes
0 – 99.9 m
50 m, buzzer No
0 – 99.9 m
5 m, buzzer No
0 – 99.9 km/h
39.9 km/h,
buzzer No
0 – 32.9 V
10.8 V, buzzer
Yes
0 – 139 °C
110 °C, buzzer
Yes
0 – 149 °C
120 °C, buzzer
Yes
0 – 9.9 bar
0.5 bar, buzzer
Yes
0 – 99 %
20 %, buzzer
Yes
0 – 99 % m
20 %, buzzer
Yes
0 – 99 %
80 %, buzzer
Yes
0 -990 rpm
300 rpm
-
-

Werbung