5.3

Mounting and installation

5.3.1
Mounting
A
1.
Place the unit on a flat surface, against a flat, closed
wall.
2.
It is possible to mount the unit to the floor. Use
brackets and adequate fasteners (A).
3.
Under condensing circumstances: It is possible to
remove the plug from the drain hole (B). Use a 1"
adapter to connect the unit to a drain tube and a
proper waste water outlet.
5.3.2
Installation
Mechanical
A
B
1.
Make two branch lines ¾" (A) on the side of the
main transport line.
NOTE
The distance between them should be at
least 500 mm. The inlet of the unit should
be connected to the first connection point in
the flow direction.
10
A
B
A
>
500mm
A
B
2.
Insert a valve (B) in each branch. Preferably, use
lockable ball valves.
NOTE
With these valves the unit can be isolated.
Keep valves closed until the unit is installed
and taken in operation. Refer to § 5.4.
A
D
3.
Connect the line (A) to the flexible outlet line (D).
4.
Connect the line (B) to the flexible inlet line (C).
Only applicable to units with direct refill connections
(-R versions):
A
B
C
1.
Insert a shutoff valve (A) and a backflow protection
(B) in the refill fluid supply line (C).