Herunterladen Inhalt Inhalt Diese Seite drucken

Important Notice - Siemens SIRIUS 3TK2830 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für SIRIUS 3TK2830:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
SIRIUS
Extension Device
Operating Instructions
Read and understand these instructions before installing, operating, or maintai-
ning the equipment.
!
DANGER
Hazardous voltage.
Will cause death or serious injury.
Disconnect power before working
on equipment.
Reliable functioning of the equipment is only ensured with certified components.
The devices must be installed in a switchgear cabinet with the IP32, IP43 or
IP54 degree of protection, depending on the ambient conditions.

IMPORTANT NOTICE

The products described herein are designed to be components of a custom-ized
machinery safety-oriented control system. A complete safety-oriented system
may include safety sensors, evaluators, actuators and signaling components. It
is the responsibility of each company to conduct its own evaluation of the effec-
tiveness of the safety system with the help of suit-ably trained persons. Sie-
mens AG and its subsidiaries and affiliates (collectively "Siemens") are not in a
position to evaluate all of the characteristics of a given machine or product or
machine not designed by Siemens.
Siemens accepts no liability for any recommendation that may be implied or sta-
ted herein. The warranty contained in the contract of sale by Siemens is the sole
warranty of Siemens. Any statements contained herein do not create new war-
ranties or modify existing ones.
Application
The 3TK2830 is used to expand the enabling circuits. You can combine it with
any 3TK28 basic unit. The maximum achievable safety category according to
DIN EN 954-1 is the category of the basic unit, providing the external circuit
(connection between the basic unit and the expansion unit) is fail-safe.
Functions and connections
The 3TK2830 has four safe enabling circuits as NO circuits and one positively-
driven NC circuit. Two LEDs indicate the operating condition.
The 3TK2830 can be controlled via any enabling circuit in the basic unit. NC cir-
cuit 51/52 of the 3TK2830 is looped into the feedback circuit of the basic unit.
The internal circuit is functionally tested by the upstream basic unit.
Terminal
Operating
A1
assignments
voltage
A2
Outputs
13, 14
23, 24
33, 34
43, 44
Feedback
circuit
51, 52
Cable lengths
3TK2830- .CB30:
.AJ20:
.AL20:
Figures
Fig. I:
Dimension drawings (dimensions in mm)
Fig. II:
Installation
Fig. III:
Internal circuit: ¿ Power pack, À Control logic,
Á Channel 1, Â Channel 2
Fig. IV:
Guard door monitoring, category 4 per DIN EN 954-1
Fig. V:
EMERGENCY STOP, category 4 per DIN EN 954-1
Fig. VI:
EMERGENCY STOP with time delay
2
L/+
N/–
Enabling circuit 1 (NO contact)
Enabling circuit 2 (NO contact)
Enabling circuit 3 (NO contact)
Enabling circuit 4 (NO contact)
3TK2830 monitoring (NC contact)
max. 1000 m
max. 300 m
max. 80 m
Order No.: 3ZX1012-0TK28-3CA1
Operating states
LED
Channel 1
Channel 2
Technical data
Permissible ambient temperature T
u
- Operation
- Storage
Degree of protection to EN 60 529
Rated insulation voltage U
i
Rated impulse withstand voltage U
imp
Rated control supply voltage U
s
Rated power
DC operating range
AC operating range 115 V / 230 V
AC operating range 24 V
Shock resistance (half-sine) as per IEC 60068
Weight
Recovery time 3TK2830-.CB30
Recovery time 3TK2830-.A.20
Release time 3TK2830-.CB30
Release time 3TK2830-.A.20
Response time 3TK2830-.CB30
Response time 3TK2830-.A.20
Utilization
Rated operational
category
voltage U
/ (V)
e
per IEC 60947-5-1
AC-15
230
DC-13
24
115
230
Continuous current I
th
Short-circuit
Fuse links
protection for
Duty class
release circuit
Be sure to fit the specified fuses. Otherwise safe interruption
in the event of a fault cannot be guaranteed.
For further data and accessories see Catalog.
3TK2830
DIN EN 60947-5-1 (08.00)
English
Operation
PS
Enabling circuits
ON
Closed
Open
Faults
• Relay fusion-welded
• Defect in electronics
• Motor contactor fusion-welded
• No supply voltage
25 to +60 °C
40 to +80 °C
IP40, IP20 at terminals
300 V
4 kV
24 V AC/DC, 115 V AC, 230 V AC
2 W
0.85 to 1.2 x U
s
0.85 to 1.1 x U
s
0.80 to 1.1 x U
s
8 g/10 ms
max. 0,26 kg
50 ms
100 ms
max. 25 ms
max. 80 ms
max. 30 ms
max. 200 ms
Rated operational
current I
/ (A)
e
with all enabling circuits loaded
40 °C
50 °C
60 °C
70 °C
5
4
3.5
3
5
4
3.5
3
0.2
0.2
0.2
0.2
0.1
0.1
0.1
0.1
5
4
3.5
3
DIAZED
gL(gG)
6 A
quick response
10 A

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis