English
READ THIS INSTRUCTION SHEET AND THE SAFETY WARNINGS CAREFULLY BEFORE
General Features
Each device has 2 selectable measuring ranges. Each device is individually temperature compensated.
2 range model
- D for display
DP0100-AZ (-D)
DP0250-AZ (-D)
* %/FS from highest pressure range (including: general accuracy, temperature drift, linearity, hysteresis
and repetition error).
The Differential Pressure Transmitter is delivered individually packed with standard accessories
(see accessories).
Dimensions
Figure 1: Dimensions in mm

Mounting Instructions

Figure 2: Installation
without jumper
(a).
jumper
(b).
The pressure values on the sticker depends on the model
(c).
Push button for zero - Zero push button zero
(d).
Figure 3: Electrical Connection
0-10 V
Output 0...10 V
4-20 mA
Output 4...20 mA
24 V
Supply 24 VAC or VDC
GND
Ground
Accessories
Standard accessories:
• 2 fixing screws
• 2 plastic duct connectors
• 2 m tube ∅ 4 / 7 mm
Optional accessories:
• Metallic duct connectors
INSTALLING AND SAVE IT FOR FUTURE USE
Measuring
Measuring
range 1
range 2
-50...+50 Pa
-100...+100 Pa
0...100 Pa
0...250 Pa
IS_DP0100 / DP0250 Rev. A_11 2009
Accuracy %/FS *
over operation temp.
-10...+50 °C
range 1 and range 2
±1,5%
±1,5%
This document is subject to change without notice
Long term
stability
typical 1 year