01--33 MONACO Mlock Instr 17.3.2010:1 – 8
The lock operates with a numeric six-digit code or a word with 6 letters. A secondary code
can be added. Each key press is confirmed with an audio and light signal.
After entry of a valid code a double signal follows. An invalid entry is followed by a long
signal. After 10 seconds without entry, an already started code entry is cancelled.
Enter code (factory code = 1-2-3-4-5-6), unlock door and open. If not opened within 3 seconds, the
lock secures automatically. If code entry failed on first attempt wait 20 seconds before re-entering.
Three long beeps indicate the lock bolt is jammed. Release the handle and re-enter code.
Locking:
Close door and turn handle fully to closing position. The lock is secured. Control blocking status by
trying to turn handle back.
Manipulation protection:
Entry of four consecutive invalid codes – keypad is blocked for 5 minutes. During this period, the
light flashes every 10 seconds and any key press causes a long signal. After expiration, entry of two
more invalid codes, restarts the 5 minute blocking period.
Safety reference:
All codes are to be securely stored. Do not use personal data (i.e. Birthdays, telephone numbers
etc.) as the code. Change the factory code before you start using the safe!
Activate the second opening code: (see fig. B)
Press and hold Key [1] until double signal. The light remains on during the following actions.
• Enter main code.
• Enter Secondary code twice (Double signal after each)
(The secondary code can be changed like the main code. With the main code, the secondary code
can be deleted. The main code cannot be deleted.)
Time Delay (max. 99 min) and open window (max. 19 min)
Press and hold key « 9 »
until double signal.
The light remains on during the following
actions.
enter manager code (double signal)
enter time delay and open window time, f.i. 2612
for 26minutes time delay and 12minutes open
window (double signal)
repeat values (double signal)
Note: changing the time delay values can
only be done in open window time.