Product Instructions
Installation
Installation instructions
DSTxs - Digital StaticTransducers xs are designed to test Nanodriver tools.
Select the correct size DSTxs, which is within the maximum torque capacity of the tool used (for example: if
using Nanodriver ERXS 50, select DSTxs 50).
DSTxs 20 cNm
Follow the instructions below to assemble DSTxs 20 cNm:
1.
Insert the coupling into the transducer and fix it by screwing the socket screw placed on the
transducer drive (figure 1).
2.
Install the DSTxs 20 cNm on a stable horizontal working station with four fixing bolts M4 (figure 2).
3.
Fasten the threaded cylinder on the transducer main body (figure 3).
4.
Install the adapter system on the main body of the DSTxs 20 cNm and screw it using three fixing
bolts M4 (figure 4).