Additional Reservoir Menu
Scottoiler offer a range of additional reservoirs that are compatible with the eSystem. These
reservoirs increase the oil capacity of the system. To keep the oil level indicator accurate it is
possible to 'add-on' one of these reservoirs. The standard screen will show 'None' meaning
there are no additional reservoirs in use. By pressing the SET button this option will cycle
through the available additional reservoirs and let the eSystem know its new capacity.
When an additional reservoir is in place the oil level gauge will display the overall
L
capacity of the system. When both the eSystem reservoir and the additional reservoir
are full the oil level should be set to 100%.
Oil Level Menu
The oil level menu allows you to set the quantity of oil present in the reservoir. By pressing the
SET button the reservoir bar will fill from 0% to 100% in 25% increments. The eSystem knows
the quantity of each oil drop and the reservoir volume therefore can keep track of your oil level
and inform you when it is running low.
When the reservoir level is 0% (i.e. empty) the system will stop to protect the pump.
L
Every time the eSystem reservoir is refilled or topped up the reservoir menu must be
reset to show this change.
Prime Menu
The prime menu allows you to run the oiler at a high rate to prime the oil delivery tubing.
When SET is pressed the system will prime for 60 seconds. Priming can be stopped at any time
by pressing the SET button again. Prime will only function if the reservoir is not empty and the
Oil Level Menu shows at least 25%.
The prime setting is usually only required on first installation but can also be used to remove air
bubbles from your oil line and to test the oiler when stationary.
Calibration Menu
In order for the triple axis accelerometer to be able to sense directional acceleration it requires
to be calibrated so that it can 'learn' its static position. To calibrate press SET on the Calibration
Menu screen.
When calibrating, the motorcycle should be upright (i.e. not on a side stand) and held steady.
Calibration is only required on first installation or if the display unit is moved to a new location
or mounting position.
Oiling Threshold Menu
The eSystem has an internal threshold that corresponds roughly to speed that is used to switch
the unit into 'oiling' () mode. The eSystem should switch to this mode between 20 – 30mph.
On smooth motorcycles the unit might not switch mode until higher speed. In this case the
oiling threshold speed can be altered from this menu. The default is level 2 but if you need to
lower the switching speed then press SET to cycle to a lower number. If you need to raise the
switching speed then press SET to cycle to a higher number.
Do not to lower the threshold to a level where it will start oiling before the motorcycle
L
starts to move.